Assembling the device
66
Connecting VOX-IO-TOUCH to the Access Manager (control unit) of the ENiQ Module
Reader or Module Reader Terminal
The 8-pin terminal for the reader of
the ENiQ Module Reader of the
VOX-IO-Touch variant (for flush
mounting or surface mounting)
This reader is connected to the ENiQ Access Manager
®
or Access Manager
Terminal via the following terminals:
External reader
Control unit (ACM/ACM-T)
Terminal 8 / +Ub
Terminal 7 / 12–24 V
Terminal 7 / GND
Terminal 8 / GND
Terminal 1 / Data “A”
Terminal 18 / RxD / A
Terminal 2 / Data “B”
Terminal 19 / TxD / B
The activation of actuators (door openers, etc.) by the control unit of the ENiQ
Module Reader ENiQ Module Reader Terminal occurs via a potential-free
relay changeover contact. A potential-free normally closed contact (N/C) and
normally open contact (N/O) are available.
You can connect potential-free switches or buttons to the inputs. These inputs
must be assigned according to the stored configuration. The standard
configuration is stored ex works. In this case, input IN1 is the door contact
(opener) and input IN2 is the release switch (closer).