![Dolmar PC-7312 HappyStart Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/dolmar/pc-7312-happystart/pc-7312-happystart_service-manual_2517201011.webp)
11
DOLMAR GmbH
1
3
4
2
3
4
5
22
18
21
19
20
17
6
8
9
5
1
2
7
05-02 Pretensioning the return spring
Wrap the starter cable as far as possible
around the drum. Hold cable tight and turn the
drum with the cable 2-3 times to pretension.
05-02 Checking the return spring
When the starter cable is fully extended, the
rope drum must still turn at least half a turn.
05-02 Removing the return spring
To remove the return spring, remove the
circlip ring (3), the return spring (4) is in a
cartridge which is fixed to the fan housing with
three screws (5).
Note: Grease new spring (944.360.000)
05-02 Mounting the return spring /starter
cable
Thread cable through, knotting (6) into the
cable drum and knotting (7) into the starter
grip (8). The washer (9) is mounted between
the starter grip and the knot.
Note: solder cable ends
05-02 Removing the starter
Remove air duct (1).
Relieve the tension on the return spring by
pulling out the starter cable (2) slightly. Hold
cable drum and remove cable from rope
drum.Let drum spool back slowly.
05 Startering system
05-03 Replacing the set of bolt/ratchet
Knock out the bolts with a punch (arrow). To
assemble, push the bolt in so far that there is
only a crack of 0.15-0.2 mm between the
ratchet and the bolt (5). For mounting the bolt,
use glue 980.009.000.