15
BD 5987 / 22.01.19 en / 088A
Your Advantages
• Safe disconnection of electrical circuits
• Line fault detection at On pushbutton
• Gold-plated contacts to switch small loads (input for PLC)
• Optionally cross fault detection in emergency stop circuit
Features BD 5987._ _:
•
According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
• Output: 2 NO contacts for AC 250 V
• 1-channel or 2-channel connection
• LED displays for channels 1 and 2
• Overvoltage and short circuit protection
• Wire connection: also 2 x 1,5 mm
2
stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or
2 x 2.5 mm
2
stranded ferruled DIN 46 228-1/-2/-3
• Width 45 mm
BD 5987._ _/001: same as BD 5987._ _ but
• Optionally automatic On function or after activation by the On pushbutton
• Optionally cross fault detection in emergency stop circuit
BD 5987.02/301: same as BD 5987.02/001 but
• Suitable also for elevators according to EN 81-20/-50
• Complies to the requirements of the directive 2014/33/EU for elevators
•
According to
- Performance Level (PL) d and category 3 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 2 to IEC/EN 62061
- Safety Integrity Level (SIL) 2 to IEC/EN 61508
• Shorter release time when opening the supply circuit
• Single-channel e-stop circuit
0221553
Safety Technique
SAFEMASTER
Emergency Stop Module
BD 5987
Product Description
The BD 5987 is used to interrupt a safety circuit in a safe way. It can be
used to protect people and machines in applications with e-stop buttons and
safety gates. The BD 5987.02/301 can be used as electronic replacement
of a safety switch according to EN 81-20, section 5.11.2.2. Applications
according to application examples M10430_a, M6745_b and M11385.
Approvals and Markings
* see variants
Canada / USA
*
Applications
Protection of people and machines
- Emergency stop circuits on machines
- Monitoring of safety gates
Indication
LED power supply:
on when operating voltage present
LED K2:
on when supply on K2
LED K3:
on when supply on K3
Fucntion Diagram
Pushbutton
On
K2
M 6742
K3
* Short-circuit detection
at the On pushbutton
*
Emergency-
stop (Off)
Block Diagram
M6758_b
A1(+)A2(-)
S33 PE(-)
S33
S33
Y2 S12 S12
S21/
PE
S22
X6
X5
33
23
13
S34 Y1
34
S23
24
14
K2
K1
K3
K1
24V
K3
K2
&
power
monitoring
logic
K2
K3
overvoltage and short-
circuit protection
All technical data in this list relate to the state at the moment of edition. We reserve the right
for technical improvements and changes at any time.
Содержание SAFEMASTER BD 5987
Страница 4: ...4 BD 5987 22 01 19 de 088A ...
Страница 14: ...14 BD 5987 22 01 19 en 088A ...
Страница 24: ...24 BD 5987 22 01 19 fr 088A ...
Страница 34: ...34 BD 5987 22 01 19 it 088A ...