18
7.1 CLEANING THE BLADE
Following the procedure described in 6.3.3, remove the protection guard. Remove any extra material that might have accumulated there, paying
attention not to touch the blade. Put back every protection panel and fasten each screw tightly.
PRECAUTION
Ensure that all guards and shields are securely and properly mounted before using the machine after the cleaning operation.
8 PROBLEMS, CAUSES AND REMEDIES
PROBLEM
LIKELY CAUSE
NOTES-SOLUTIONS
Pressing the start button, the
saw motor does not work
No tension from the electrical supply
system
Check the mains and cables
USE CAUTION
The plug is not inserted properly
Make sure the connection is correct
The start button is faulty or damaged
Replace the button
USE CAUTION
The saw does not cut
The blade is mounted in the wrong
direction
Turn the blade
USE CAUTION
The blade is getting blunt
Sharpen the blade or replace it
The machine stops during
the operation
A piece is stuck along the blade
Switch off the machine and follow the procedure at paragraph
7.1
CAUTION
The plug is not connected
Establish a proper connection
9 MAINTENANCE
9.1 PLANNED GENERAL MAINTENANCE
A regular maintenance of the machine, besides prolonging its life cycle, helps to guarantee more safety during operations.
DANGER
DO NOT REPAIR, REGISTER, LUBRICATE OR CLEAN ANY MOVING PARTS
Ensure that the electric cable is disconnected from the mains, or that the shaft drive is not connected to the actuator shaft, before
starting any maintenance operation on the saw.
DANGER
IT IS COMPULSORY TO WEAR GLOVES
Regularly verify the wear of the blade and, if necessary, replace it by strictly following the procedure described in 6.3.3, paying
attention to avoid sharp edges.