7 – 2 – 4    Start sectioning   

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 

 
 
 
 
 
 

1. Touch SLIDE PREPARATION (ONLINE) on the 

touch panel of the Main Unit. 

 
 
 
 
 
 
 
 
 
 
 
 

2. The preoperational check screen will be displayed. 

Check the blade, the tape, the remaining slide 
numbers, the drip water and the humidify water that 
are prepared sufficiently for the process. Touch OK.

 

 
 
 
 
 
 
 
 

3. Select the tray number of which the block is set. 
(24-sample feeder will not indicate)

   

 
 
 
 
 
 
 
 
 

4. Change the section making function such as 

ON/OFF setting of each item if necessary. Check 
other setting such as roughing, then touch START. 

 

Preoperational blade change: Blade change at the 

beginning with ON. 

Print: Print onto the slides with ON.

 

Auto trimming: Auto trimming with ON.

   

RATIO(%) : Setting of the trimming %. 
Blade mark detection

Blade mark check with ON.   

ABORTED : System performs blade change if the 

blade marks continuously occurs. 

 

Operation start check screen 

                       

(AS-410 panel screen) 

 

Main Menu screen 

(AS-410 panel screen) 

 

Preoperational check screen 

(AS-410 panel screen)

 

 

Sample selection screen 

 

 

Содержание LK-400

Страница 1: ...ckage AS 410 series Read the Operation Manual before using LK 400 for correct use Keep the Operation Manual near the product for quick reference when needed The LK 400 option is dedicated to the Auto...

Страница 2: ......

Страница 3: ...however any questionable points inaccuracies or omissions should be found please inform us Keep LK 400 Operation Manual near the product for quick reference when needed Read Operation Manual for Auto...

Страница 4: ...th the applicable instructions for correct use may result in personal injury or material damage This sign means that failure to comply with the applicable instructions for correct use may result in de...

Страница 5: ...tart up and the configuration of LK 400 application 4 1 The screen configuration of LK 400 application 4 2 Start up the Main Unit 4 3 Start up of the LK 400 application 4 4 Log in 4 5 Setting and conf...

Страница 6: ...ension Module Package 7 2 4 Start sectioning 8 Troubleshooting 9 Specifications 9 1 Specification table 9 2 Available characters for printing and slide printing range 9 3 Available barcode types for r...

Страница 7: ...the PC Method 2 The System executes the section preparation operation based on the manual input data and sample tray numbers By connecting with an external system such as a pathological diagnosis sup...

Страница 8: ...stored in the slide collection box 1 3 LK 400 data link diagram LK 400 Data matching Sample identification information Cassette barcode Sectioning information Sectioning thickness Number of sections S...

Страница 9: ...ng Unit 100 Slide Collection Box Dry Chamber Option DU 100 400 Slide Collection Box Dry Chamber Option DU 400 PC USB Touch panel LK 400 requires to have the following units and options Main Unit Dry C...

Страница 10: ...ce using a cassette printer 2 Turn ON the power of LK 400 PC and start up the system 3 Create a file of the sample identification number barcode read by the terminal PC of external system of the neces...

Страница 11: ...start up the system 3 Start up LK 400 Software Log in then select the Manual Input Mode 4 Place the embedded sample cassette on the sample tray of AS 410 5 Enter the necessary information in the LK 40...

Страница 12: ...ement of AS 410 and LK 400 Connect the AS 410 and the LK 400 PC with supported LAN cable crossing cable LK 400 PC AS 410 Main Unit This example shows the System with BS 96 DU 400 SS FS and BR options...

Страница 13: ...e of connecting the LAN with an external system such as a server of the pathological diagnosis support system and a terminal PC connect the expanded LAN port and the LAN hub LK 400 PC LAN connection E...

Страница 14: ...e placed in the AS 410 The system refers shared folder for the Auto Sectioning Mode the system refers temporary folder for the Retry Mode and the Manual Input mode Regarding the files in the shared fo...

Страница 15: ...the Operation Manual for more detail When the section preparation completes the data of the corresponding block will be deleted from the shared folder 3 2 File The System verifies the file name and t...

Страница 16: ...of the sectioning section m Sex Sex Date of birth Date of birth Age Age Tissue name Name of the tissue part of the block Comment Institutional department Date of issue Date of issue of registration o...

Страница 17: ...d the configuration of LK 400 personal computer 4 1 The screen configuration of LK 400 application The following configuration are the screen images of the controlled menu Configuration screens of the...

Страница 18: ...o operate each mode Ensure that the LAN cable of the AS 410 and the LK 400 PC is connected properly To change the user s registration or the stain information registration enter the administer autoriz...

Страница 19: ...administer to change e g addition and deletion of the stain information LK 400 distributes the saved file informationuch as the stain code the sectioning thickness and the slide type automatically Inp...

Страница 20: ...error occurs if the name of the registered slide type is not matched with the registered slide name in the Main Unit Ensure to input the registered slide name Caution 3 The Add stain Information scree...

Страница 21: ...line then click the Edit button 2 For the stain information change change the following information Stain Code 0 to 999 Stain Type The character input on the slide Thickness 3 to 10 Glass Type Slide...

Страница 22: ...hange Password After change click the Save User Setting screen User Setting Registration screen User Setting Password change screen User Setting Deletion screen The confirmation prompt will be display...

Страница 23: ...istory shows the stored slide records of the prepared slides e g the prepared date and time the user the specimen number the stain name the thickness of the section and the sectioned block number The...

Страница 24: ...displayed in the Error History screen Select the file to save the information if necessary The caution error and the PC error will not be recorded in this log Error History screen 4 5 6 Termination of...

Страница 25: ...and log in Then execute the following procedure 1 Click Auto Sectioning Mode button from the Main Menu of LK 400 2 The Auto Sectioning Mode screen will be displayed 5 1 Descriptions of the screen Dis...

Страница 26: ...are to be produced An estimated time It varies depending on the settings for the rough cutting auto trimming and the print settng etc Editing of the Stain Sectioning Condition Click this box to change...

Страница 27: ...No 96 set on the far left corner of the bottom tray Set the sample blocks on the tray from the position No 1 to the next without skipping any position The Auto Sectioning Mode stops serching the block...

Страница 28: ...eeder does not have this step 4 Change the Slide preparation settings or ON OFF settings for each operation conditions as needed Check other settings such as roughing and polishing then touch START Pr...

Страница 29: ...ble to select perform or not perform the changes of stain code number and sectioning after acquisition of the information 5 Click START on the LK 400 control screen 6 The completion dialog screen is d...

Страница 30: ...on Turn ON the AS 410 power start up the LK 400 application and log in Refer to 4 3 Start up the LK 400 and 4 4 Log in 1 Click Retry Mode after Main menu is displayed 2 Retry Mode screen is displayed...

Страница 31: ...with the blocks to be sectioned A System with the 24 sample feeder does not have this step 4 Change the Slide preparation settings or ON OFF settings for each operation conditions as needed Check oth...

Страница 32: ...ble to select perform or not perform the changes of stain code number and sectioning after acquisition of the information 5 This screen is displayed after the data completes reading 6 Click START on t...

Страница 33: ...al Input Mode Manual Input Mode Initial screen of Manual Input Mode Start Start sectioning after entering the sectioning information Acquire sample information system reads the sectioning condition if...

Страница 34: ...7 2 2 Input method of the sectioning information Manual Input method 1 Place the cursor to the Block ID 2 Read the barcode on a sample cassette with the handy barcode reader 3 Click Acquire sample inf...

Страница 35: ...e sure to correctly coordinate the numbers with the section condition data and or print information Ensure to confirm visually that the positioned sample and the slide print are matched Warning Nos Ma...

Страница 36: ...4 sample feeder will not indicate 4 Change the section making function such as ON OFF setting of each item if necessary Check other setting such as roughing then touch START Preoperational blade chang...

Страница 37: ...the data reference The following screen will be displayed after the completion of the checks 6 Click Start button of the LK 400 PC to execute the sample block check 7 Complete message displays after c...

Страница 38: ...400 and the slide conditions entry are correct Refer to the Chapter 6 Daily Maintenance of the AS 410 Operation Manual 5 The system cannot read the cassette barcode Remove the paraffin waste around th...

Страница 39: ...ode and Manual Input Mode are not selected Select one of the sectioning mode then touch OK on the LK 400 PC screen to continue After the system checks the communication with the LK 400 PC the left scr...

Страница 40: ...r Error of the requested numbers of slide preparation condition Ensure the numbers of the sample block and the slide preparation condition is matched ensure the setting is within the tolerance value 1...

Страница 41: ...mote PC Symptom Communication error PSD receiving error Slide storage data Time out or response error No response from the PC for the slide storage data transmission Check the LK 400 screen if there i...

Страница 42: ...pe Operating environment Exclusive PC OS Windows7 Professional USB port Handy barcode reader Liquid crystal monitor a Mouse a Keyboard a DVD drive Expansion LAN board AS 410 Main Unit connection Opera...

Страница 43: ...Circumflex P p _ Underscore Q q back quote R r Left curly bracket brace S s Vertical line T t Right curly bracket brace U u Tilde V v W w X x Y y Z z Because the CSV file uses comma symbol as a delim...

Страница 44: ...n Module Package 9 3 Available barcode types for reading Barcodes Code39 ITF Industrial 2or5 COOP 2or5 NW 7 Codebar Code 128 GS1 128 EAN 128 GS1 DaraBar RSS Code 93 JAN EAN UPC Trioptic Code 39 2D Cod...

Страница 45: ...r s responsibility to make a backup of the important data in case of emergencies 2 Any loss caused by the use of this product the loss caused by the unavailability of this product including loss of pr...

Страница 46: ...Auto Slide Preparation System Extension Module Package...

Отзывы: