20
9800 Series Installation and Programming Guide | Digital Monitoring Products, Inc.
Site Code Position and Length
Enter the site code start position and length in the data
string. Press select area 2 to clear the site code start position
and enter a number between 0-255. Press
CMD
to save.
Default is
1
.
Press select area 4 to clear the site code length and enter a
number between 1-24. Press
CMD
to save. Default is
8
.
User Code Position and Length
Define the user code start bit position and length. Press
select area 2 to clear the user code position and enter a
number between 0-255. Press
CMD
to save. Default is
9
.
Press select area 4 to clear the user code length and enter a
number between 16-64. Press
CMD
to save. The default is the
DMP value of
16
.
Require Site Code
Press the top row select key or area under
YES
to use a site
code and press
CMD
to view the site code entry display.
Press
NO
to advance to
NO OF USER CODE DIGITS
. Default
is
NO
.
In addition to user code verification, door access is only
granted when any one site code programmed at the
SITE
CODE ENTRY
option matches the site code received in the
Wiegand string.
SITE CODE
POS:
1
LEN:
8
USER CODE
POS:
9
LEN:
16
REQUIRE SITE
CODE:
NO
YES