Digital Monitoring Products, Inc. | 734N-WIFI Installation and Programming Guide
7
Use the included 333 suppressor with
the 734N-WIFI to suppress any surges
caused by energizing a magnetic lock
or door strike.
Install the 333 across the 734N-WIFI
C
(common) and
NO
(normally open) or
NC
(normally closed) terminals.
If the device being controlled by the
relay is connected to the
NO
and
C
terminals, install the suppressor on the
NO
and
C
terminals.
Conversely, if the device is connected
to the
NC
and
C
terminals, install
the 333 Suppressor on
NC
and
C
terminals.
The suppressor wire is non-polarized.
Install the suppressor as shown in
Figure 6.
4
INSTALL THE 333 SUPPRESSOR
RED
PROG
J2
RED
J5
RED
KYPD IN
J4
KYPD OUT
J1
DATA
XMT LED
WIEGAND
READ LED
RELAY
ON
NC
C
NO
GRN
YEL
RED
+ –
Piezo
734N-Wi-Fi
Figure 6: 333 Suppressor
Installation on the 734N-WIFI