734N Series Installation and Programming Guide | Digital Monitoring Products, Inc.
This product is not intended for outside wiring as covered by Article 800 in the National
Electrical Code, NFPA 70.
Category 5e cabling is minimum performance category recommended. The performance
category utilized should match the transmission speed required at the installation site.
Compliance with IEEE 802.3 (at or af) specifications was not verified as part of UL 294B.
The equipment is intended to comply with the following sections of the National
Electrical Code, ANSI/NFPA 725.121.
The minimum conductor gauge permitted to connect between the PSE or power
injector and the PD shall be 26 AWG (0.13 mm
2
) for patch cords; 24 AWG (0.21 mm
2
) for
horizontal or riser cable.
Use Cat 5 568‑B wiring for connections. See Figure 14.
The equipment shall be provided with information concerning
the power sourcing equipment (PSE) connector configuration
(for example, Alternative A or Alternative B or both), and the
maximum power class supported by the PSE.
The 734N‑POE is compatible with the Altronix Netway 1.
Figure 14: Cat 5 568‑B
Wiring