Digital Monitoring Products, Inc. | 734N Series Installation and Programming Guide
29
Gateway Address
Press a select key or area to enter the local gateway address
of the module. Default is
192.168.0.1
.
Panel IP Address
Press a select key or area to enter the IP address of the
panel. Default is
192.168.0.1
.
Note:
This IP address must match the address
programmed in the panel at the Local IP Address option
in Network Options. The DHCP programming in the
panel must be set to
NO
.
Panel IP Port
Press a select key or area to enter the port number that the
module uses to send communication to the panel. This must
be the same port that is programmed in the 734N Listen Port
in Network Options programming of the panel. The panel IP
port cannot be the same as the panel network programming
port. Default is
2002
.
734N Passphrase
You must enter an 8‑16 character alphanumeric passphrase to
encrypt communication with the panel. The 734N passphrase
must match the one entered in panel Network Options. The
passphrase is blank by default.
GATEWAY ADDRESS:
192.168.0.1
PANEL IP ADDR:
192.168.0.1
PANEL IP PORT:
2002
********
734N PASSPHRASE:
Содержание 734N Series