OSDP Status Indicator Outputs
Terminals 6 and 7 provide connections for Remote Annunciation and Armed Status
indicators.
RA (Remote Annunciation)
Remote Annunciation provides an unsupervised switched ground for a remote
annunciator that turns on when the Zone 2 Bypass timer expires. Connect the wire from
the RA Terminal to a remote annunciator. The remote annunciator silences when the RA
restores. The remote annunciator (RA) switched ground operates even if the speaker is
programmed not to operate.
AS (Armed Status)
Armed Status provides an unsupervised switched ground for a visual or audible armed
status indicator that turns on when the burglary areas are armed, such as SYSTEM ON or
ALL SYSTEM ON. Connect a wire from the AS Terminal to an armed status indicator.
Caution:
Status indicator outputs support a maximum of 100 mA per terminal.
Exceeding the maximum rating on LC, RA, or AS terminals can damage equipment.