revision: 0
FlexxPump 125 (24V)
User Manual
65
EN-
SCHMIERSYSTEME
D I R E C T L U B R I C A T I O N S Y S T E M S
D L S
9.
Maintenance and disposal
Before starting any maintenance work, inform yourself about the general safety
instructions (see Chapter 2) and observe the relevant local and operational safety
regulations.
Do not deactivate any protective device without authorization!
9.1
Maintenance schedule
The following maintenance schedule must be observed for the FlexxPump 125:
Maintenance
Commis-
sioning
After 500
hours or after
3 months
Every
year
If required
Cleaning
x
x
x
x*
Visual check
x
x
x
x*
Cartridge change
x**
x***
x*
*
Depending on operating conditions and lubricant consumption
**
Depending on delivery status (ordered version)
***
Recommendation after 2 years at the latest