on). When you enter the FIL-Menu, you will return to the ON mode, even if you cancel
FIL prematurely with CLR.
The microelectronics integrated in the FlexxPump 125 permanently monitors the status.
In the event of irregularities, an addressed error message is displayed on the LCD. The
red LED flashes every 5 seconds and also signals an error optically.
LCD
Name Description
Remedy
Error
E1
Cartridge Error;
Cartridge not
recognized or
corrently not
mounted
Place a new cartridge on
FlexxPump 125 (see chapter
9.2).
No confirmation of the error
necessary; it is automatically
cleared after the remedial
action.
Error
E1
Cartridge
(Symbol) empty
Place a new cartridge on
FlexxPump 125 (see chapter
9.2).
No confirmation of the error
necessary; it is automatically
cleared after the remedial
action.
Error
E2
Overload; the
back pressure
at the lubricati-
on point is too
high.
Check the lubrication point
and eliminate the cause of the
fault.
Switch FlexxPump 125 off
(OFF) and on (ON) again.
Error
E3
Undervoltage
Switch FlexxPump 125 off
(OFF).
Check the power supply.
Switch FlexxPump 125 on
(ON).
E1
E2
E3
E1
6.4
Error codes