revision: 0
FlexxPump 125 (24V)
User Manual
26
EN-
SCHMIERSYSTEME
D I R E C T L U B R I C A T I O N S Y S T E M S
D L S
Display in LCD Meaning
Chapter
dark
Power supply not connected
6.3.3
OFF
FlexxPump 125 is switched off
6.3.3
On
FlexxPump 125 is ready for operation; FlexxPump 125
dispenses lubricant in accordance to the operation
mode and the set values
6.3.3
PUL
FlexxPump 125 is ready for operation in the Pulse-Con-
trol-Mode PUL and is waiting for control signal from
external control (PLC)
8
PUL (flashing)
FlexxPump 125 receives a control signal from the exter-
nal controller (PLC).
8
---
Received control signal longer than 15 sec.
8.2
Errors
E1
Error E1 (Empty cartridge / no cartridge detected)
6.4
E2
Error E2 (Overload)
6.4
E3
Error E3 (Undervoltage)
6.4
E4
Error E4 (fatal error)
6.4
Sub-Menu
INF
INF-Menu
6.3.4
6.3.5
6.3.6
n01
Firmware version of the FlexxPump 125
h06
Currently set value of the pause time h
c01
Currently set value of the number of cycles c
6
Currenty set value of the emptying time Et
PUL
Currently set operation mode Pulse-Control-Mode
125
Currently set cartridge size
SET SET-Menu
6.3.7
-h-
Operating mode Hour-Mode
Et
Operating mode Empty-Time-Mode
PUL
Operating mode Pulse-Control-Mode
125/250
Adjustable value of the cartridge size
RUN
RUN-Menu
6.3.8
01...50
During the manually triggered active RUN command
("Quick-Check"/special donation), the LCD displays the
approximate back pressure in bar. In addition, the green
LED lights up.