9024-066-A-1-15
31
12345678
ON
123
ON
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
KEY
SWITCH
NO
NC
3 BUTTON
CONTROL
SW1
SW2
OFF
ON
POWER
P4
6
1 2 3 4 5 6 7 8 9 10
5.1 Terminal Descriptions
SECTION 5 - MAIN TERMINAL WIRING
UL 325 Terminal
See pages 27 - 29
NOT
Used
Relay
Contacts
OPEN Non-Contact Sensor
CLOSE Non-Contact Sensor
OPEN Contact Sensor
CLOSE Contact Sensor
Low V
oltage Common
Low V
oltage Common
OPEN
CLOSE
STOP
Common
Main T
erminal Input LEDs
W
Main Terminal Input
LEDs Note:
The LED
that is beside the main
terminal wiring input
will light when that
terminal input gets
activated.
W
M
M
M
L
tha
WE
M
M
M
L
th
WE
M
M
M
M
L
L
L
L
th
h
E
M
M
M
M
L
L
L
L
th
h
h
h
E
M
M
M
M
L
L
L
th
h
h
E
M
M
M
L
L
L
th
E
E
M
M
L
t
ER
R
M
M
t
ER
R
M
R
R
R
R
#2
#10
Low Voltage Common
Full Open
24 VAC - 250 mamp. max.
Not Used
Low Voltage Common
Not Used
Low Voltage Common
Not Used
Low Voltage Common
Reverse / Stop
Low Voltage Common
24VDC Accessories
Relay
Relay
Low Voltage Common
Not Used
Not Used
Low Voltage Common
Not Used
Not Used
20-Pin Main Terminal
10
12
13 14
Operation of relay is dependent on
setting of SW 1,
switches 6 and 7
.
Relay contacts
can be set for
Normally Open (NO) or Normally
Closed (NC) operation.
Contact rating is
1 amp maximum
at 24-volts DC.
ON
12
3
4
5
67
8
SW 1
NC
NO
ON
1
2
34567
8
SW 1
SW1,
switch 8 MUST be OFF
:
24-VDC 500 mA constant power
can be provided for desired
accessories wired to terminal 12.
DO NOT
turn ON
SW1, switch 8.
Photo
Sensor
Terminals 1, 2 and 3 are ALWAYS powered up. Even
when circuit board has powered down to manage the
power drain on the batteries.
ONLY
connect
opening devices
to terminal 2.
This input ONLY functions when gate is
fully
opened
or in the
closing cycle
.
•
When gate is closing: SW 1,
switch 4
is
OFF,
an input to main terminal 10 (eg: photo beam
gets obstructed) will
reverse
and open the gate.
Note:
If the auto-close timer is ON,
when gate reaches the open position,
timer will time out and close the gate.
•
When gate is closing: SW 1,
switch
4
is
ON,
an input to main terminal 10
(eg: photo beam gets obstructed) will
stop
the gate, then continue to close
the gate when input is clear (Used to
help prevent tailgating vehicles from unauthor-
ized entry). See page 24 for more information.
ON
12
3
4
5678
SW 1