1812-065-V-12-14
1
8
MASTER
CODE
ON
MASTER
CODE
ON
16.5
VAC
Main
Terminal
1871-010
Phone In
(1-2)
Phone Out
(4-5)
MAST
MAST
COD
Relay 1
Relay 2
Power
16.5
VAC
Main
Terminal
1871-010
Phone In
(1-2)
Phone Out
(4-5)
MAST
MAST
COD
Relay 1
Relay 2
Power
Be sure to properly ground
ALL
1812s.
See page 13 for
acceptable grounding sources.
Relay 2 to Access Control Device
To 24 VAC Supplied Transformer
To 24 VAC Supplied Transformer
Relay 1 to Access Control Device
Relay 2 to Access Control Device
Relay 1 to Access Control Device
1.10 Wire Multiple 1812s - Intercom Mode
Cat5e
See previous
page for
wiring and
information
on relays
and power
transformer.
See previous
page for
wiring and
information
on relays
and power
transformer.
To the next 1812’s PHONE OUT
terminals 4 and 5 wired in the series,
if desired.
Up to five (5) 1812s may be
wired in series
using the method
shown: 1st 1812’s PHONE IN to
2nd 1812’s PHONE OUT; 2nd
1812’s PHONE IN to 3rd 1812’s
PHONE OUT, etc.
Each 1812 must have a unique
ATTENTION NUMBER (See 2.3.3)
and a unique MASTER CODE (See
2.2).
The 1812 that is the
furthest away
from the phone
or PBX / KSU
system must be programmed for
INTERCOM MODE. All other 1812
units in the series are
programmed for TELEPHONE
MODE (See 2.3.1).
Be sure to properly ground
ALL
1812s.
See page 13 for
acceptable grounding sources.
Ground 12 AWG Min.
Ground 12 AWG Min.
Phone Out
Phone Out
Phone In
Phone In
1st 1812
Phone Mode
2nd 1812
Phone Mode
3rd 1812
Phone Mode
4th 1812
Phone Mode
5th 1812
INTERCOM MODE
Phone Out
Phone Out
Phone In
Phone In
Phone Out
Cat5e
Connect to Homeowner’s
Telephone
Connect the 1st 1812’s PHONE OUT
terminals directly to homeowner’s
phone or an un-used C.O. port on a
PBX or KSU system.
TIP
RING
TIP (+):
White/blue mark
RING (-):
Blue/white mark
Telephone Line
For complete
information,
see page 12.
Check Polarity of Telephone Line
Check for polarity on the incoming telephone line to
each 1812 board and maintain polarity throughout
the telephone line to the homeowner’s phone. One
potential problem checked when a malfunction
occurs in a telephone entry system is to see if the
telephone line has been wired to each board with
the correct polarity.
Test Example: 1st 1812 board’s PHONE IN
terminals #1 and #2. Terminal #2 must be positive
(Tip +) with respect to terminal #1 (Ring -). Set a
VOM meter to measure DC volts. Place the positive
lead on terminal #2 and the negative lead on
terminal #1.
If the meter shows a positive voltage
- OK
. If the meter shows a negative voltage (needle
moves off scale to the left), reverse the wires on
terminals #1 and #2.
Older Lines
Green Wire (+)
Older Lines
Red Wire (-)
Maximum 1812 Wiring
Configuration
When multiple 1812 systems are
connected together, maintain
common polarity on ALL phone lines.
Phone
Jack
Cordless Phone Base Station
Cordless
Option
Remote phones throughout house.
Homeowner’s Phone
LAN/Cordless
Homeowner’s Phone
LAN/Cordless
RJ-11
Phone
Connector
77
88
99
44
55
66
00
Push Button
Push Button
To Call
To Call
77
88
99
44
55
66
00
Push Button
Push Button
To Call
To Call
77
88
99
44
55
66
00
Push Button
Push Button
To Call
To Call
77
88
99
44
55
66
00
Push Button
Push Button
To Call
To Call
77
88
99
44
55
66
00
Push Button
Push Button
To Call
To Call
18
17
16
Com
15
N.C.
14
N.O.
13
Com
12
N.C.
11
N.O.
10
9
8
7
6
5
RING
4
TIP
3
GND
2
TIP
1
RING
24
VAC
18
17
16
Com
15
N.C.
14
N.O.
13
Com
12
N.C.
11
N.O.
10
9
8
7
6
5
RING
4
TIP
3
GND
2
TIP
1
RING
24
VAC
1st 1812
2nd 1812
DO NOT
wire the
wireless adapter to the
PHONE OUT main
terminal connection.
Please refer to the
“Wireless Adapter”
manual 1815-560 for
correct wiring.
Wireless Adapter
Содержание 1812 Classic
Страница 2: ......
Страница 45: ...1812 065 V 12 14 43 ...