1812-065-V-12-14
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
MASTER
CODE
ON
1871-010
1.11 Main Terminal Description
Phone Out
(Twisted Pair)
Time Clock
Relay 1
(Access Control Device)
Relay 2
(Access Control Device)
Input Power
(Transformer)
Back-Up
Battery Power
Emergency
and/or Postal
Entry Switch
1.
Phone In (Negative - Ring)
2.
Phone In (Positive - Tip)
3.
Ground
(Required)
4.
Phone Out (Positive - Tip)
5.
Phone Out (Negative - Ring)
6.
External Time Clock Input. Connect Common to terminal 9.
7.
Switch Input Relay 1. A switch closure across terminals 7 & 9
will activate relay 1 for its programmed strike time.
8.
Switch Input Relay 2. A switch closure across terminals 8 & 9
will activate relay 2 for its programmed strike time.
9.
- 24 VDC Battery Negative. Also
Common
for terminals 6, 7 & 8.
10.
+ 24 VDC Battery Positive.
11.
Relay 1 Normally Open
12.
Relay 1 Normally Closed
13.
Relay 1
Common
14.
Relay 2 Normally Open
15.
Relay 2 Normally Closed
16.
Relay 2
Common
17.
24 VAC Input Power
18.
24 VAC Input Power
External time clock input may be
used to create an
additional
time
zone for access codes (4.14).
The 1812 Classic can be programmed from the system keypad (Keypad on the 1812) or from a touch-tone telephone connected
to the system.
System Keypad (Preferred)
We strongly recommend that you become familiar with the entire programming sequence before attempting to program
some of the more complex features of this system using the system keypad. If you make a single error in the program-
ming steps, you will have to re-do the sequence from the beginning.
Touch-Tone Telephone
The programmable features that can be programmed using the system keypad can also be programmed using a touch-
tone telephone (typically the house phone) connected to the 1812. This method of programming is useful for program-
ming simple steps or for turning certain features ON or OFF, but is not recommended for complex programming steps.
•
•
2.1 Programming Methods
Direct “System Keypad”
Touch-Tone Telephone
connected directly to
the system or off-site.
SECTION 2 - PROGRAMMING
Before You Start Programming: IMPORTANT!
Make sure the 1812 has power and we strongly suggest that you become
familiar with these programming instructions before beginning any programming of the 1812 Classic system.
The 1812 has been programmed at the factory with many of the programming parameters already set (default setting) for a
typical residential application with a single 1812. There is no need to reprogram these parameters unless you want to change
them. For easy reference, refer to the chart on page 22 that list the various programming functions and their default settings.
77
88
99
44
55
66
1
2
3
00
1111
2222
333333
Push Button
Push Button
To Call
To Call
DE
Note: Each relay can control a
normally open
OR
normally close
access control device. Relay
contacts are rated for 3 amps @
30 VAC maximum.
MAS
MAS
CO
Relay 1
(11-13)
Relay 2
(14-16)
Phone In
(Twisted Pair)
Wireless
Adapter
(Polarity Matters!)
OR
DO NOT
wire the
wireless adapter to the
PHONE OUT main
terminal connection.
Please refer to the
“Wireless Adapter”
manual 1815-560 for
correct wiring.
Wireless Adapter
1.
Phone In (Negative - Ring)
Содержание 1812 Classic
Страница 2: ......