- 8 -
Note:
1.
Safety distances for Wave flame machine are indicated in above picture. At least 15m in all projection directions, at least 5m to the other
sides of the device. In order to indicate correct direction, please place the top panel correctly.
2.
Open the top cover of the flamer from the "OPEN" position, take out the flame fluid can, and add the fuel.
3.
The nozzle is still hot after the flamer worked, to prevent burns, do not touch, wait for natural cooling.
5.4.2.
Quick Operation Sheet
Immediately upon receiving the machine, carefully unpack the carton, check the machine received in good condition. Ensure safety operation
of machine, please do following below operation procedures when operate flame machine.
Operation
step
Schematic
diagram
Explanation
1
Installation
The device can only be placed horizontally, if placed on truss, please locked with extra safety cables.
2
Locate safety
lock at TEST
MODE
Before operate machine please locate safety lock at TEST MODE.
Under TEST MODE, operator can test the rotation of nozzle, but the fuel ejection function is disabled
to prevent firing.
Under USER MODE: the device can run normally. Please strictly follow the safety distance requirement.
Human beings, animal or flammable objects shall be away from the danger area.
3
Fueling
Take out the flame fluid can and add fuel; carefully put it back into the cabinet to avoid spilling; ensure
that the tube is placed in the fluid can; tighten the container cap. Please use the designated suitable
fuels.
4
Power and DMX
cable
connection
Two power supplies are available for selection: 1). 110V/220V main power supply; 2). 12V battery
power supply.
5
Setting for
adjustment of
the angle
Setting for adjustment of the angle
Disconnect the DMX signal and adjust the angle selection. It can be adjusted to full angle mode and
other fixed angle modes. When adjusting to the full-angle mode, you need to place the limit bar on
the protective fence to the maximum angle position, or remove the protective fence. Otherwise, the
rotating motor will be damaged and the machine will not rotate normally.
6
Switch ON the
machine
Please confirm safety lock located at TEST MODE before switch on the unit.
7
Set DMX
address
The unit has 6 channels. Detailed information please refer to DMX channels.
8
Pressurize
Under DMX control: Channel 6= 50~200.
9
Check device
status in TEST
MODE
Reconfirm safety lock located at TEST MODE before test. In this status, the nozzle will rotate, and
igniter will be activated, but there is no flame effect because no fuel output. In case DMX control is
used to test the sequence, It is suggested to set CH1 at 128, so that nozzle stays at straight up
position after firing.