Wave Sequence List: 

45 

Step  6>10 

LONG flame 

L -> R 

1.35 s 

135-137 

46 

Step  10>6 

LONG flame 

R -> L 

1.35 s 

138-140 

47 

Step  4>6>8>10>12 

LONG flame 

L -> R 

3.01 s 

141-143 

48 

Step  12>10>8>6>4 

LONG flame 

R -> L 

3.01 s 

144-146 

49 

Step 8>6>10>4>12 

LONG flame 

M>L>R>L

>R 

2.67 s 

147-149 

50 

Step 8>10>6>12>4 

LONG flame 

M>R>L>R

>L 

2.67 s 

150-152 

No. 

Ignition angle NO. 

Description 

Nozzle 

movement 

Firing Duration 

(For reference) 

Duration (For 

reference) 

CH5 DMX 
Reference Value 

51 

Wave  5 -->11 

Middle wave sequence 

L -> R 

1.99 s 

153-155 

52 

Wave  11-->5 

Middle wave sequence 

R -> L 

1.99 s 

156-158 

53 

Big wave  1--15 

LONG wave sequence 

L -> R 

4.14 s 

159-161 

54 

Big wave  15--1 

LONG wave sequence 

R -> L 

4.14 s 

162-164 

55 

Wave  8-->1 

Middle wave sequence 

M -> L 

2.18 s 

165-167 

56 

Wave  8-->15 

Middle wave sequence 

M -> R 

2.18 s 

168-170 

57 

Wave  1-->8 

Middle wave sequence 

L -> M 

2.16 s 

171-173 

58 

Wave  15-->8 

Middle wave sequence 

R -> M 

2.16 s 

174-176 

59 

Wave  8-->11 

SHORT wave sequence 

M -> R 

1.12 s 

177-179 

60 

Wave  8-->5 

SHORT wave sequence 

M -> L 

1.12 s 

180-182 

61 

Wave  5-->8 

SHORT wave sequence 

L -> M 

1.24 s 

183-185 

62 

Wave  11>--8 

SHORT wave sequence 

R -> M 

1.24 s 

186-188 

63 

Step  2>14 

SHORT flame Step sequence 

L -> R 

2.16 s 

189-191 

64 

Step  14>2 

SHORT flame Step sequence 

R -> L 

2.16 s 

192-194 

65 

Step  2>14 

LONG flame Step sequence 

L -> R 

7.62 s 

195-197 

66 

Step  14>2 

LONG flame Step sequence 

R -> L 

7.62s 

198-200 

67 

Step  8>14 

SHORT flame Step sequence 

M -> L 

1.08 s 

201-203 

68 

Step  8>2 

SHORT flame Step sequence 

M -> R 

1.08s 

204-206 

69 

Step  8>14 

LONG flame Step sequence 

M -> L 

3.81s 

207-209 

70 

Step  8>2 

LONG flame Step sequence 

M -> R 

3.81s 

210-212 

71 

 

 

Step 3>13 

SHORT flame Step sequence 

L -> R 

1.8s 

213-215 

72 

Step 13>3 

SHORT flame Step sequence 

R -> L 

1.8s 

216-218 

73 

Step 4>12 

SHORT flame Step sequence 

L -> R 

1.4s 

219-221 

74 

Step 12>4 

SHORT flame Step sequence 

R -> L 

1.44s 

222-224 

75 

Step 5>11 

SHORT flame Step sequence 

L -> R 

1.08s 

225-227 

76 

Step 11>5 

SHORT flame Step sequence 

R -> L 

1.08s 

228-230 

77 

Step 7>9 

SHORT flame Step sequence 

L -> R 

0.36s 

231-233 

78 

Step 9>7 

SHORT flame Step sequence 

R -> L 

0.36s 

234-236 

79 

Step 3>13 

LONG flame Step sequence 

L -> R 

6.35s 

237-239 

80 

Step 13>3 

LONG flame Step sequence 

R -> L 

6.35s 

240-242 

Содержание FLAME MACHINE HF-210

Страница 1: ......

Страница 2: ...ollow the instruction in the manual when operate flame machine HF 210 If you have any doubts please contact DJPOWER Use the HF 210 only under the rules and instructions from this manual Contact DJPOWER in case of doubts about the usage We assume that you your employees and others who use or come in contact with the machine are familiar with how the machine should be handled This includes proper us...

Страница 3: ... the machine before operation and keep a safe distance between the person and the equipment The Safe distance for the HF 210 is at least 15m in all projection directions at least 5m to the other sides of the device Before connect the power cable communication DMX cable should well connected and ensure the command keep at firing OFF status And safety lock stay at test mode The operator responsible ...

Страница 4: ...ght burst swing flame etc It is suitable for all kinds of shows to create excellent atmosphere 2 2 Features Fitted with dual valves pumps safer and more stable Fast and precise flame burst With tilt sensor design output is auto off when tilts to 45 in any direction Unique safety lock to avoid false triggering Rainproof design for the fuel nozzle thicken and anti rust metal structure durable in use...

Страница 5: ...l panel Wireless Control Wire Control Maximum Output Height Appr 8 10 meters no wind condition Effect Angles 210 150 Fluid Consumption Rate Appr 0 48 min L Consumable Isopropyl alcohol Bio Ethanol Isopar G It is a must to add 10 20ML castor oil to every 10L of fuel to protect the pump from being damaged Machine Net Weight 28 kg Flightcase Net Weight 8 kg Gross Weight 40 kg Machine Dimensions 588 3...

Страница 6: ...e Blue AC Ground Green Yellow Green Yellow 4 3 Resetting the Breaker This product is equipped with a resettable breaker If the breaker trips all sections of this product will lose power Remove the power cord from mains power Reset the breaker by pressing the button with your finger Plug the product s power cord into the power outlet and continue using as recommended 5 OPERATION 5 1 Preparing for O...

Страница 7: ...to the standby page 5 3 2 Menu Map 显示屏 描述 参数范围 Starting Page HF 210 REV1 0 AC 230V 50Hz Initializing P 0 V 12 When the external trigger function is ON showing this page Standby Page Wait To Connect P 0 V 12 When the external trigger function is OFF to connect to DMX control showing this page Working Status Page DMX address 1 P 0 V 12 Under DMX control showing the DMX address setting Ready To Work ...

Страница 8: ...t No fuel pump failure pipeline problem etc E2 Tip Err P 0 V 12 The machine tilts over 45 it stops running system will report E6 E3 Bat Err P 0 V 12 Machine stops running due to battery voltage higher than15V or lower than 10V for 5s contentiously Possible fault the battery is low E4 System Lock P 0 V 12 Safety lock located at TEST MODE E5 Relief Err P 0 V 12 Pressure relief error due to pipeline ...

Страница 9: ...all be away from the danger area 3 Fueling Take out the flame fluid can and add fuel carefully put it back into the cabinet to avoid spilling ensure that the tube is placed in the fluid can tighten the container cap Please use the designated suitable fuels 4 Power and DMX cable connection Two power supplies are available for selection 1 110V 220V main power supply 2 12V battery power supply 5 Sett...

Страница 10: ...able objects are within the danger area 12 Pressurize Under DMX control Channel 6 50 200 13 Firing Under DMX control Channel 3 255 14 Pressure Relief Relief pressure when show finished or Wave flame machine will not be used for a long period Under DMX control Channel 6 0 49 or 201 255 15 Switch safety lock to TEST MODE Guarantee safety use for next time 16 Power off Power off Wave flame machine te...

Страница 11: ...ngle Ignition SHORT flame Static 0 56s 54 56 19 60 Single Ignition SHORT flame Static 0 56s 57 59 20 45 Single Ignition SHORT flame Static 0 56s 60 62 21 30 Single Ignition SHORT flame Static 0 56s 63 65 22 15 Single Ignition SHORT flame Static 0 56s 66 68 23 0 Single Ignition SHORT flame Static 0 56s 69 71 24 15 Single Ignition SHORT flame Static 0 56s 72 74 25 30 Single Ignition SHORT flame Stat...

Страница 12: ... sequence M L 1 12 s 180 182 61 Wave 5 8 SHORT wave sequence L M 1 24 s 183 185 62 Wave 11 8 SHORT wave sequence R M 1 24 s 186 188 63 Step 2 14 SHORT flame Step sequence L R 2 16 s 189 191 64 Step 14 2 SHORT flame Step sequence R L 2 16 s 192 194 65 Step 2 14 LONG flame Step sequence L R 7 62 s 195 197 66 Step 14 2 LONG flame Step sequence R L 7 62s 198 200 67 Step 8 14 SHORT flame Step sequence ...

Страница 13: ...top 5 4 6 1 About Channel 1 The first channel controls the firing angle It defines to which angle the nozzle of Wave flame machine move to The angle can be chosen anywhere between 105 to 105 DMX value 0 to 255 2 The DMX value for angle of 0 is 127 5 round up 128 Use this value following formula can be used to calculate all other angles in degree Please always note the prefix of the angle DMX Value...

Страница 14: ...quence Three DMX values can be used for one of the programmed firing sequence from above sequence list refer to above sequence list table Below formula can be used to calculate firing sequence Sequence No DMX Channel Value 3 Note Channel 5 overrides Channel 1 2 3 and 4 in case the value is from 3 255 CH6 Channel 6 Mode The sixth channel is the working mode of pump When the safety lock located at T...

Страница 15: ...ing mode 50 200 4 Firing Nozzle will firing and make movement from start point to end point Note After firing The DMX value of CH3 must back to 0 before an ignition can be made again Make sure CH 5 0 2 3 Example of firing with fixed duration 1 Set nozzle straight up CH1 Angle 128 CH2 Speed 0 CH3 Ignition 0 CH4 Opening time 0 CH5 Program sequence 0 CH6 Firing mode 50 200 2 Set firing duration 1s CH...

Страница 16: ......

Отзывы: