- 6 -
5.2.
On-device Control Panel
To access the control panel functions, use the four buttons located underneath the LCD display.
5.3.
On-device Control Mode & Operation
5.3.1.
Programming
•
Refer to the Menu Map to understand the menu options. The menu map shows the main level and a variable number of programming
levels for each option.
•
To go to the desired main level, press <MENU> repeatedly until the option shows on the display. This will take you to the first
programming level for that option.
•
To select an option or value within the current programming level, press <TIMER> < >
or <VOLUME>< > until the option shows
on the display. If there is another programming level, you will see that first option, or you will see the selected value.
•
Press <MENU> repeatedly to switch menu pages.
•
Press <STOP> to return to the standby page.
5.3.2.
Menu Map
显示屏
描述
参数范围
Starting Page
HF-210 REV1.0
AC-230V 50Hz
Initializing...
P:0 V:12
When the external trigger function is ON, showing
this page.
Standby Page
Wait To Connect
P:0 V:12
When the external trigger function is OFF, to
connect to DMX control, showing this page
Working Status Page
DMX address 1
P:0 V:12
Under DMX control, showing the DMX address
setting.
Ready To Work
P:0 V:12
When external trigger is ON and the unit is
connected to external trigger, after pressurization
is completed, it shows this page.
Menu Page
DMX address
1
Setting DMX address
1~512
Ext Ignite
ON
Setting External fireworks ignitor status
Please use 9-60V fireworks ignitor signal
ON/OFF
Set ExtSequence
85
Setting Preset sequence triggered by fireworks
ignitor
1~85
Button
Function
<MENU>
Switch menu pages to select a function
▲
Increases the numeric value of current function
▼
Decreases the numeric value of current function
<ENTER>
Switch between current menu page and Standby Page