djpower FLAME MACHINE HF-210 Скачать руководство пользователя страница 3

 

- 2 - 

1.5.

 

Safety Notes 

Please read the following Safety Notes carefully before working with the product. The notes include important safety information about 
installation, usage, and maintenance. 

 

1.5.1.

 

Personal Safety 

 

 

Make sure that children, unauthorized people and animals do not obtain access to the machine. 

 

After the machine is turned on, it is strictly forbidden to stay in the dangerous area of the machine. Safety distances for HF-210: At least 
15m in all projection directions, at least 5m to the other sides of the device. 

 

Please prepare dry powder and fire extinguishing equipment at the machine use place. Always have a dry powder fire extinguisher, CO2 
fire extinguisher, and an extinguishing blanket in case of needed. 

1.5.2.

 

Mounting and Rigging 

 

CAUTION: When transferring product from extreme temperature environments, (e.g. cold truck to warm humid ballroom) condensation 
may  form  on  the  internal  electronics  of  the  product.  To  avoid  causing  a  failure,  allow  product  to  fully  acclimate  to  the  surrounding 
environment before connecting it to power. 

 

Do not mount the product on a flammable surface (linoleum, carpet, wood, paper, carton, plastic, etc.). Keep a safe distance from the 
unit, the unit can only be placed horizontally. 

1.5.3.

 

Power and Wiring 

 

Please use a grounded socket to avoid the risk of electric shock. 

 

Make sure power supply in consistent with the rated voltage of the equipment, Unplug and turn off the machine when not use. 

 

Check that the power cord is not pinched or damaged. 

 

Do not connect the machine to a dimming controller or varistor. 

 

Do not disconnect the power supply by pulling the power cord. 

1.5.4.

 

Operation 

 

The maximum ambient temperature is 40 ° C. Do not operate the machine in a high temperature environment. 

 

Do  not  operate  this  product  if  the  machine  casing  or  cable  is  damaged.  Immediately  ask  the  authorized  technician  to  replace  the 
damaged part. 

 

Make sure there are no flammable materials around the machine before operation, and keep a safe distance between the person and 
the equipment. The Safe distance for the HF-210 is: at least 15m in all projection directions, at least 5m to the other sides of the device. 

 

Before connect the power cable, communication DMX cable should well connected and ensure the command keep at firing OFF status. 
And safety lock stay at test mode 

 

The operator responsible for the control of Wave flame machine must always have a clear view of the device, so that he/she can stop 
the show immediately when there is danger. The main AC power switch should near operator. So that operator can turn off the power 
of all devices in case of abnormal. 

 

If there be any doubt as to the safety operation of the device in any circumstances, the device should be taken out of service immediately. 
Be sure the device is in good operating condition before use, check the sparkle oil, fuse, cable and power plug. If fail to fire correctly, 
immediately shut down and contact the factory. 

 

Empty the Flame Fluid Can before transporting the machine. 

 

The machine does not contain any user disassembled and self-repaired or modified parts. Do not attempt to repair or modify the machine 
yourself without any training or authorized technicians to avoid damage or malfunction.

 

 

Notes for use of Battery power supply:  Wave flame  machine  HF-210 with stable  internal circuit design, please support  the unit  with 
battery voltage higher than 12V. The driving speed of motor won’t change because of the decrease of battery power supply. Battery 
options: 12V lead-acid battery (above 30AH, with more than 24h standby). For Lithium battery, please use battery with output above 
30A. 4 pin sound coupliers (1+ connect 12V anode, 1- connect 12V cathode). Connecting power cables should above 14AWG. 

 

Be sure to use the suitable flame fuel indicated in the user manual, otherwise, it is easily lead to failure or danger. Do not add any material 
other than the specified proportion of castor oil in the oil drum. Be careful when refill the flame fluid tank. Please keep flame fluid away 
from heat source, sparks, fire or other possibility of ignition.

 

 

Содержание FLAME MACHINE HF-210

Страница 1: ......

Страница 2: ...ollow the instruction in the manual when operate flame machine HF 210 If you have any doubts please contact DJPOWER Use the HF 210 only under the rules and instructions from this manual Contact DJPOWER in case of doubts about the usage We assume that you your employees and others who use or come in contact with the machine are familiar with how the machine should be handled This includes proper us...

Страница 3: ... the machine before operation and keep a safe distance between the person and the equipment The Safe distance for the HF 210 is at least 15m in all projection directions at least 5m to the other sides of the device Before connect the power cable communication DMX cable should well connected and ensure the command keep at firing OFF status And safety lock stay at test mode The operator responsible ...

Страница 4: ...ght burst swing flame etc It is suitable for all kinds of shows to create excellent atmosphere 2 2 Features Fitted with dual valves pumps safer and more stable Fast and precise flame burst With tilt sensor design output is auto off when tilts to 45 in any direction Unique safety lock to avoid false triggering Rainproof design for the fuel nozzle thicken and anti rust metal structure durable in use...

Страница 5: ...l panel Wireless Control Wire Control Maximum Output Height Appr 8 10 meters no wind condition Effect Angles 210 150 Fluid Consumption Rate Appr 0 48 min L Consumable Isopropyl alcohol Bio Ethanol Isopar G It is a must to add 10 20ML castor oil to every 10L of fuel to protect the pump from being damaged Machine Net Weight 28 kg Flightcase Net Weight 8 kg Gross Weight 40 kg Machine Dimensions 588 3...

Страница 6: ...e Blue AC Ground Green Yellow Green Yellow 4 3 Resetting the Breaker This product is equipped with a resettable breaker If the breaker trips all sections of this product will lose power Remove the power cord from mains power Reset the breaker by pressing the button with your finger Plug the product s power cord into the power outlet and continue using as recommended 5 OPERATION 5 1 Preparing for O...

Страница 7: ...to the standby page 5 3 2 Menu Map 显示屏 描述 参数范围 Starting Page HF 210 REV1 0 AC 230V 50Hz Initializing P 0 V 12 When the external trigger function is ON showing this page Standby Page Wait To Connect P 0 V 12 When the external trigger function is OFF to connect to DMX control showing this page Working Status Page DMX address 1 P 0 V 12 Under DMX control showing the DMX address setting Ready To Work ...

Страница 8: ...t No fuel pump failure pipeline problem etc E2 Tip Err P 0 V 12 The machine tilts over 45 it stops running system will report E6 E3 Bat Err P 0 V 12 Machine stops running due to battery voltage higher than15V or lower than 10V for 5s contentiously Possible fault the battery is low E4 System Lock P 0 V 12 Safety lock located at TEST MODE E5 Relief Err P 0 V 12 Pressure relief error due to pipeline ...

Страница 9: ...all be away from the danger area 3 Fueling Take out the flame fluid can and add fuel carefully put it back into the cabinet to avoid spilling ensure that the tube is placed in the fluid can tighten the container cap Please use the designated suitable fuels 4 Power and DMX cable connection Two power supplies are available for selection 1 110V 220V main power supply 2 12V battery power supply 5 Sett...

Страница 10: ...able objects are within the danger area 12 Pressurize Under DMX control Channel 6 50 200 13 Firing Under DMX control Channel 3 255 14 Pressure Relief Relief pressure when show finished or Wave flame machine will not be used for a long period Under DMX control Channel 6 0 49 or 201 255 15 Switch safety lock to TEST MODE Guarantee safety use for next time 16 Power off Power off Wave flame machine te...

Страница 11: ...ngle Ignition SHORT flame Static 0 56s 54 56 19 60 Single Ignition SHORT flame Static 0 56s 57 59 20 45 Single Ignition SHORT flame Static 0 56s 60 62 21 30 Single Ignition SHORT flame Static 0 56s 63 65 22 15 Single Ignition SHORT flame Static 0 56s 66 68 23 0 Single Ignition SHORT flame Static 0 56s 69 71 24 15 Single Ignition SHORT flame Static 0 56s 72 74 25 30 Single Ignition SHORT flame Stat...

Страница 12: ... sequence M L 1 12 s 180 182 61 Wave 5 8 SHORT wave sequence L M 1 24 s 183 185 62 Wave 11 8 SHORT wave sequence R M 1 24 s 186 188 63 Step 2 14 SHORT flame Step sequence L R 2 16 s 189 191 64 Step 14 2 SHORT flame Step sequence R L 2 16 s 192 194 65 Step 2 14 LONG flame Step sequence L R 7 62 s 195 197 66 Step 14 2 LONG flame Step sequence R L 7 62s 198 200 67 Step 8 14 SHORT flame Step sequence ...

Страница 13: ...top 5 4 6 1 About Channel 1 The first channel controls the firing angle It defines to which angle the nozzle of Wave flame machine move to The angle can be chosen anywhere between 105 to 105 DMX value 0 to 255 2 The DMX value for angle of 0 is 127 5 round up 128 Use this value following formula can be used to calculate all other angles in degree Please always note the prefix of the angle DMX Value...

Страница 14: ...quence Three DMX values can be used for one of the programmed firing sequence from above sequence list refer to above sequence list table Below formula can be used to calculate firing sequence Sequence No DMX Channel Value 3 Note Channel 5 overrides Channel 1 2 3 and 4 in case the value is from 3 255 CH6 Channel 6 Mode The sixth channel is the working mode of pump When the safety lock located at T...

Страница 15: ...ing mode 50 200 4 Firing Nozzle will firing and make movement from start point to end point Note After firing The DMX value of CH3 must back to 0 before an ignition can be made again Make sure CH 5 0 2 3 Example of firing with fixed duration 1 Set nozzle straight up CH1 Angle 128 CH2 Speed 0 CH3 Ignition 0 CH4 Opening time 0 CH5 Program sequence 0 CH6 Firing mode 50 200 2 Set firing duration 1s CH...

Страница 16: ......

Отзывы: