- 7 -
Tip switch
ON
Setting the tilt protection
(In case it is ON, if the machine tilts over 45° , it
stops the unit from firing)
ON/OFF
WindowLight
ON
Setting LED light which illuminates the fluid level
indicator
ON/OFF
Angle Selection
Full Angle
Angle selection
Full Angle , Left
105 , Left 90 , Left
75 , Left 60 , Left
45 , Left 30 , Left
15,middle 0,right
15 , right 30 , right
45 , right 60 , right
75 , right 90 , right
105
language
English
Language setting
Error and Warning
Page
E1: Pressure Err
P:0 V:12
Pressure failed to reach 100% after 13s
pressurizing, system will report E1.
Possible fault: No fuel; pump failure; pipeline
problem etc.
E2: Tip Err
P:0 V:12
The machine tilts over 45° , it stops running,
system will report E6
E3: Bat Err
P:0 V:12
Machine stops running due to battery voltage
higher than15V or lower than 10V for 5s
contentiously.
Possible fault: the battery is low.
E4: System Lock
P:0 V:12
Safety lock located at TEST MODE
E5: Relief Err
P:0 V:12
Pressure relief error due to pipeline can't release
pressure.
Possible fault: pressure release valve failure;
pipeline problem or control system problem etc.
5.3.3.
Menu Map Setup
Press MENU to enter the setting interface. Press MENU to enter different options until you return to the main interface.
5.4.
Operation
5.4.1.
Orientation