TROUBLESHOOTING FLOWCHARTS
25
ALL BILLS ARE REJECTED
All bills are rejected.
Main Power
Disconnected.
Apply power
Blown Fuse
Check fuses and
replace if
necessary.
Loose connection.
Check cable at bill
validator, controller board,
and cable connection to
coin mech.
Coin mechanism low on
coins.
Fill coin tubes.
Bill path obstructed / dirty.
Clear / clean
path.
Wrong option switch
settings.
Reset.
Incompatible bill validator.
Replace.
Defective bill validator.
Replace.
Defective controller
board.
Replace.
Check in
diagnostics
"NA".
If fuse is blown,
controller will
have no power.
Is coin
mech
functional?
Test in
diagnostics
to ensure
mdb is
running.
Sensor error. If
possible, DEX and
look at Master Error
Report.
Verify
machine is
not in sold
out.
Verify
Limited
Access is
disabled or
Off.
Check STS
to confirm
all
selections /
columns
are
assigned.
Содержание DPSL5 E
Страница 38: ...WIRING DIAGRAMS AND SCHEMATICS 37 SBC...
Страница 39: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 38 Refrigeration Circuit Diagrams...
Страница 40: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 39...
Страница 53: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 52 INNER DOOR...
Страница 63: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 62 CABINET INTERIOR 1A 1C 1E 1D...
Страница 73: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 72 SCREWS NUTS...
Страница 75: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 74 WASHERS BOLTS MISC HARDWARE...