PROGRAMMING
21
Note:
To remove the EPROM after programming is complete turn power off,
ground
yourself on the vender cabinet before removing the EPROM
, remove the EPROM,
turn power on, test vender for proper operation.
III.
Manual Reprogramming (all 804,919,240.11 or if an EPROM does not automatically reprogram
the SBC)
•
At power up, the current software version will be displayed. To manually program the control board with
the new software, press the blue service switch on the SBC to enter the service menu. Advance to the
“Auto Test” menu by holding buttons 1& 2 simultaneously. Enter Auto Test by pressing button 1, and
advance to the “Reprogramming Microprocessor” submenu by holding buttons 1& 2 simultaneously.
•
At the “Reprogramming Microprocessor” prompt, press button 1. “THIS OPERATION REPROGRAMS
VENDOR” shows on the display. Press button 1 at this prompt. Next display will show “BUTTON 2 =
REPROGRAM, BUTTON 3 = EXIT”.
•
Press button 2 to reprogram vender with the new software. “Reprogramming Vendor…” displays while the
red LED on the board blinks rapidly for 3-4 seconds. Verify the new software version, and previous
settings return to the display. If the new software version (the software version of the newly installed
EPROM) shows on the display, the SBC software has been successfully updated.
Note:
To remove the EPROM after programming is complete, remove power to the
vender,
ground yourself on the vender cabinet before removing the EPROM
, remove
the EPROM, while still grounded install a label on the microprocessor showing the
revision of software that is installed in the SBC, power the vender back on and test for
proper operation.
Figure 1
IV.
Dr Pepper SL5 DN501E-10
machines model number resetting to update the space to sales
(software revisions 804,919,240.41C, 804,919,240.51 and higher). This is needed due to number
1 and number 2 select buttons flavor specifications being permanent.
•
The software revisions listed must be updated in the machine through either step II or III
before the new space to sales changes will work.
•
After the new software is updated, make sure the vending machine’s door is open.
•
Remove power to the machine, by unplugging it from the outlet or at the stack plug..
•
Reapply power to the machine.
•
At power up the current software version and model number will scroll across display.
•
After the current model number is displayed, press select button 1. Then display will show
“MODL” for set model number.
Locators
Locators
Label on microprocessor to show
what revision of software is in SBC
if EPROM is removed after
reprogramming
.
Содержание DPSL5 E
Страница 38: ...WIRING DIAGRAMS AND SCHEMATICS 37 SBC...
Страница 39: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 38 Refrigeration Circuit Diagrams...
Страница 40: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 39...
Страница 53: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 52 INNER DOOR...
Страница 63: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 62 CABINET INTERIOR 1A 1C 1E 1D...
Страница 73: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 72 SCREWS NUTS...
Страница 75: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 74 WASHERS BOLTS MISC HARDWARE...