![Dixie Narco DPSL5 E Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/dixie-narco/dpsl5-e/dpsl5-e_technical-manual_2511158014.webp)
PROGRAMMING
13
ENAB -
Enable
This function is used to allow the lighting routine to go in to affect.
Press select button 1 and the current setting will be displayed (On or Off).
Press and hold select button 1 to toggle between “On” and “Off”.
Release the select button showing the setting you wish to use and display will return to “ENAB”.
Press select buttons 1 & 2 to scroll to “RTN”.
RTN -
Return
Press select button 1 to return to “LT”.
Press & hold select buttons 1 & 2 simultaneously to move to the next item on the menu.
RFRG – Refrigeration:
available only when Environmental Controls are set to on.
This function is used to electronically control the refrigeration operations of the vender if an electronic temp
sensor is being used. Press select button 1 will enter “TEMP”.
TEMP
– Temperature
(Default Temperature 35
0
F / 1.5
0
C)
This function is used to set the average product temperature for initial pull down and reload recovery.
Press select button 1 and “tt.tx” will show on the display where x is F (Fahrenheit) or C (Celsius) and tt.t is the
degrees.
Press and hold select button 1 to increase or decrease the number by 1 F
0
or 0.5
0
C. Release select button with
the display showing the temperature you wish to use and display will return to “TEMP”.
Press select buttons 1 & 2 to scroll to “Celsius or Fahrenheit”.
C-F - Celsius or Fahrenheit
This function is used to set the degree reading to Fahrenheit (F) or Celsius (C).
Press select button 1 and the current setting will show on the display. Press and hold select button 1 to toggle
between F and C. Release the select button with the display showing the setting you wish to use and display will
return to “Celsius or Fahrenheit”.
Press select buttons 1 & 2 to scroll to “DSP”.
DSP - Display
This function is used to enable the Temperature to be displayed following the “Ice Cold Drink” message.
Press select button 1 and “DSP” will show on the display. Press select button 1 and the current setting will be
displayed (On or Off). Press and hold select button 1 to toggle between “On” and “Off”.
Press & hold select buttons 1 & 2 simultaneously to move to the next item on the menu.
DAYS -
DAYS
This function is used to set the days of the week to use Temperature Setting Routine.
Day of Week:
SUN - Sunday
WED - Wednesday
SAT – Saturday
MON - Monday
THUR - Thursday
ALL - All Days
TUE - Tuesday
FRI – Friday
NONE – No Days
RTN - Return
Press select button 1 and "MON #" will show on the display, where # is “0” (disable) or “1” (enable). Press and hold
select button 1 to toggle between “0” and “1”. Release the select button with the display showing the setting you wish
to use. Press select buttons 1 & 2 simultaneously to scroll through all available days, “ALL”, “NONE”, and “RTN”.
Press select button 1 at the “RTN” prompt returns to “DAYS”.
Press & hold select buttons 1 & 2 simultaneously to move to the next item on the menu.
STRT -
Start
This function is used to set the hours and minutes for storage temperature to become active.
Press select button 1 and the current four digit hour and minute setting will be displayed (24 hour).
Press and hold select button 1 to Set Hours.
Press and hold select button 2 to Set Minutes.
Press and hold select buttons 1 & 2 to simultaneously to move to the next item on the menu.
Содержание DPSL5 E
Страница 38: ...WIRING DIAGRAMS AND SCHEMATICS 37 SBC...
Страница 39: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 38 Refrigeration Circuit Diagrams...
Страница 40: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 39...
Страница 53: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 52 INNER DOOR...
Страница 63: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 62 CABINET INTERIOR 1A 1C 1E 1D...
Страница 73: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 72 SCREWS NUTS...
Страница 75: ...PARTS LIST NA Not Applicable Part numbers subject to change without notice 74 WASHERS BOLTS MISC HARDWARE...