6
XR06CX
EN
1. FRONT PANEL COMMANDS
To display or change target set point,
in programming mode it selects a parameter or confirm an operation.
To start a manual defrost.
In programming mode it browses the parameter codes or increases the displayed value.
In programming mode it browses the parameter codes or decreases the displayed value.
KEYS COMBINATION
+
To lock or unlock the keyboard.
+
To enter the programming mode.
+
To return to room temperature display.
LED MODE
MEANING
ON
Compressor enabled
FLASHING
Anti short cycle delay enabled
ON
Defrost in progress
FLASHING
Dripping in progress
ON
Fans output enabled
FLASHING
Fans delay after defrost
ON
Measurement unit
FLASHING
Programming mode
ON
Measurement unit
FLASHING
Programming mode
HOW TO SEE THE SET POINT
1
Push and immediately release the
key, the set point is displayed;
2
Push and immediately release the
key or wait about 5s to return to the display of the temperature.
HOW TO CHANGE THE SETPOINT
1
Push the
key for 3 seconds , the Set point is displayed and the and the “°C” or “°F” LED starts blinking;
2
To change the Set value push the
or
arrows. Then push the
again to confirm.
NOTE:
the set value is stored even when the procedure is exited without pressing the
key.
HOW TO START A DEFROST
Push the
key for at least 4 seconds and a manual defrost will start.
HOW TO CHANGE A PARAMETER VALUE
To change the parameter’s value operate as follows:
1
Enter the Programming mode by pressing the
+
keys for 3s “°C” or “°F” LED start blinking;
2
Select the required parameter through
or
keys;
3
Press the
key to display its value;
4
Change its value through
or
keys;
5
Press
again to store the new value and move to the following parameter.
To exit:
Press
+
or wait 30s without pressing a key.
NOTE:
the set value is stored even when the procedure is exited without pressing the
key.
HIDDEN MENU
The hidden menu includes all the parameters of the instrument; how to enter the hidden menu:
1
Enter the Programming mode by pressing the
+ keys for 3s. “°C” or “°F” LED start blinking;
2
Released the keys, then push again the
+
keys for more than 7s. The L2 label is displayed, immediately followed by the Hy parameter.
NOW YOU ARE IN THE HIDDEN MENU
.
3
Select the required parameter, browsing the displayed parameters through the
and
keys;
4
Press the
key to display its value;
5
Change its value through the
or
keys;
6
Press
to store the new value and move to the following parameter.
To exit:
Press
+
or wait 30s without pressing a key.
NOTE:
the set value is stored even when the procedure is exited by waiting the time-out to expire.
HOW TO MOVE A PARAMETER FROM L2 TO L1
Each parameter present in the second level (HIDDEN MENU) can be removed or put into “THE FIRST LEVEL” (user level) by pressing
+
.
In the HIDDEN MENU (L2) when a parameter is present in the First Level, the decimal point LED is on.