© Copyright 2003-2019 Dive Lab® Inc. All rights reserved.
This Guide is made available for the express use of owners and users of the Dive Lab XLDS systems.
This information is subject to periodic updates and changes. Always check the Dive Lab web site for the latest versions.
Document XLDS Guide – Section Four A
Revised September 30, 2019
17
SECTION FOUR A: RDC REPAIR / MAINTENANCE / OVERHAUL
Figure 12
Figure 13
Figure 14
5. Lubricate, then stack the following items:
spring pad (11), spring (10), SS washer (12),
bearing (13), SS washer (12), two item (14).
Figure 15
6. Ensure the lower body threads have been
lightly lubricated, then carefully load the top
of the body, down onto the lower body snug
with moderate force, using the oil filter
wrench.
7. Liberally lubricate the end of the stem (16), as
well as the threads, and secure into the top of
the body.
Figure 16
8. The regulator should now be tested for
proper operation.
Low Pressure Umbilical Supply
Valves / Cross-Connect Valves
Overhaul
The quarter turn valves used for the LP cross
connect and umbilical supply are very reliable,
and require only minimal maintenance.
The valve is made of 316 stainless steel, and have
a rated working pressure for the XLDS of 400 psig.
The valve should be overhauled at least every five
years, or whenever the valve does not operate
smoothly, or if any leakage occurs. The valve is
simple to disassemble and service, however, the
person
performing
service
must
be
knowledgeable and properly trained. The cross-
connect valve and the umbilical supply valve, use
the same components, except for the nylon
locking nuts. Overhaul is done in the same
manner.
NOTICE
Make sure the top washer (14), has the
tapered hole bevel facing up, for smooth
engagement to the stem (16).