- 29 -
0DT872 01-12-2021
2. TECHNICAL CHARACTERISTICS
Ref. Description
1
Lateral plate of the transom
2
Transom
3
Rolling shaft
4
Linear Encoder (SLE)
5
Polyzene guide upper section
6
Polyzene guide lower section
7
Fixing plate of the guide
8
Angular vertical post
9
Supporting spring
10
Fixing screw
11
Column cover
Ref. Description
12
Geared motor K22
13
Manual driving device
14
Manual driving rod
15
Electronic board
16
Photocell
17
Polyester curtain
18
PVC transparent window
19
Vertical re reinforcing strips
20
Bottom edge with sand ballast
21
Motor carter and opposite side plate cover
Correctly size the line conductor cross-section by referring to the indicated absorption and taking the length and
installation of the cables into account.
7
5
4
6
8
10
9
16
1
21
5
6
8
3
18
17
20
19
11
2
1
12
13
21
14
15
CONTROL PANEL INVERTER (52E)
Power supply voltage ................................................................................................................... 230 V monofase 50/60 Hz
Line sizing ...................................................................................................................................................................16 A
Auxiliary control power voltage ...................................................................................................................................24V
Motor rating ..................................................................................................................................................................0,6 KW
Control board protection class .........................................................................................................................................IP 66
Operating temperature ...........................................................................................................................................- 5 + 50 °C
EN