- 28 -
0DT872 01-12-2021
CONTENTS
Chap. Topic
.....................................................................................................................................
Page
1.
GENERAL SAFETY PRECAUTIONS
.......................................................................................28
2.
TECHNICAL CHARACTERISTICS
...........................................................................................29
3.
MECHANICAL INSTALLATION
3.1
Check of the opening ............................................................................................................ 30
3.2
Assembly on the floor
............................................................................................................ 30
3.3
Door fixing
............................................................................................................................. 30
3.4
Gear motor K22 .................................................................................................................... 30
3.5
Installation of the safety device SLE (Safety Linear Encoder) .............................................. 30
3.6
Curtain positioning ................................................................................................................ 30
3.7
Column cover fixing
.............................................................................................................. 30
3.8
Motor and side plate cover fixing
..........................................................................................30
3.9
Transom cover fixing
............................................................................................................. 30
4.
ELECTRICAL CONNECTIONS
4.1
Motor connection .................................................................................................................. 31
4.2
SLE connection (primary safety) ...........................................................................................32
4.3
Connections to the control board ..........................................................................................32
5.
ELECTRONIC CONTROL PANEL
5.1
52E (inverter) - connections .................................................................................................. 33
6.
PROGRAMMING MENU
6.1
Installation menu ................................................................................................................... 38
6.2
Advanced menu .................................................................................................................... 39
6.3
Timed opening menu ............................................................................................................ 40
6.4
Service menu ........................................................................................................................ 41
6.5
Display messages ................................................................................................................. 41
6.6
Interlock ................................................................................................................................41
7.
ADJUSTING AND STARTING
7.1
Adjustment of the Safety Linear Encoder (SLE) ................................................................... 42
8. TROUBLESHOOTING
.............................................................................................................. 43
9. MAINTENANCE
........................................................................................................................ 44
All right reserved
All data and specifications have been drawn up and checked with the greatest care. The manufacturer cannot however take
any responsibility for eventual errors, ommisions or incomplete data due to technical or illustrative purposes.
Optional accessory
1. GENERAL SAFETY PRECAUTIONS
This installation manual is intended for professionally
competent personnel only.
The installation, the electrical connections and the settings
must be completed in conformity with good workmanship
and with the laws in force.
Read the instructions carefully before beginning to install the
product. Incorrect installation may be a source of danger.
Packaging materials (plastics, polystyrene, etc) must not be
allowed to litter the environment and must be kept out of the
reach of children for whom they may be a source of danger.
Before beginning the installation check that the product is in
perfect condition.
Do not install the product in explosive areas and atmospheres:
the presence of flammable gas or fumes represents a serious
threat to safety.
Before installing the door, make all the structural modifications
necessary in order to create safety clerance and to guard or
isolate all the compression, shearing, trapping and general
danger areas.
Check that the existing structure has the necessary strength
and stability.
The safety devices must protect against compression, shearing,
trapping and general danger areas of the motorized door.
Display the signs required by law to identify danger areas.
Each installation must bear a visible indication of the data
identifying the motorised door.
Before connecting to the mains check that the rating is
correct for the destination power requirements.
A multipolar isolation switch with minimum contact gaps of 3
mm must be included in the mains supply.
Check that upstream of the electrical installation there is an
adequate differential switch and a suitable circuit breaker.
Ensure that the motorised door has an earth terminal in
acwireance with the safety adjustements in force.
The manufacturer of the door declines all responsability in
cases where components which are incompatible with the
safe and correct operation of the product only original spare
parts must be used or whenever modifications of any nature
are made that have not been specifically authorised by the
manufacturer.
For repairs or replacements of products only Ditec original
spare parts must be used.
The fitter must supply all information corcerning the automatic,
the manual and emergency operation of the motorised door or
gate, and must provide the user the device with the operating
instructions.
Safety Top
T
Safety Top L
T L