background image

 

2/12 

 

Device Markings (Symbols) 

Certain markings (symbols) can be found on the controller and are 

defined as: 

Symbol 

Description 

 

CE marking: the device conforms to the requirements 

of applicable EC directives. 

 

Products must be disposed of at the end of their 

useful life according to local regulations. 

 

Read the Hardware Installation Guide for more 

information. 

 

UL marking: conforms to the requirements of the UL 

certification.  

 

FCC marking: This device complies with FCC rules 

part 15, subpart B, class B. 

 

Warning Symbol: Significant information required. 

Refer to the Hardware Installation Guide. 

 

Alternating Current 

 

Direct Current 

General Wiring Recommendations 

 

Turn off power before any kind of servicing. 

All wiring must comply with electrical wiring diagrams as well as 

national and local electrical codes.  

To connect the wiring to a controller, use the terminal connectors. 

Use a small flat screwdriver to tighten the terminal connector 

screws once the wires have been inserted. 

Power type cables (i.e. for power, 2- and 3-wire voltage and current 

inputs and outputs, as well as triac outputs) should be kept apart 

from other types of wiring to avoid any ambient noise transmission 

to other wires.  

The board connectors accept wires or flat cables ranging from 22 to 

14AWG (0.644  to  1.630mm diameter) per pole. However, power 

cables must be  between 18 and 14AWG (1.024  to  1.630mm 

diameter). 

Do not connect the universal inputs, analog/digital outputs or 

common terminals  to earth or chassis ground (unless stated 

otherwise). 

Keep all wires away from high speed data transmission cables (for 

example, Ethernet, etc.). 

Keep input and output wiring in conduits, trays or close to the 

building frame if possible. 

Controller Dimensions & Components 

 

Figure 2:  

VAVS-O, VAVS, VAV & VVTS series dimensions 

Low pressure

High pressure

Bracket 

mouting kit

190 [7.48 ]

54  

[2

.13 

]

61

.5  

[2

.42

]

10 

[0.40]

3 mm

0.12 in

26

.5  

[1

.04

]

11 

[0.43] 

5  

[0

.2

Units Legend: mm [in]

 

Figure 3:  

VAV-N & ECL-103 series dimensions 

PRESSURE

LOW

E

D

E

D

Actuator Clutch for 

Manual Adjustment

HIGH

Opening for 

Damper Shaft

Mechanical Stops

Pressure Sensor Inputs (when equipped)

Service Pin

Connectors

Integrated 

Mounting 

Brackets

Damper Shaft 

Clamping Mechanism

 

Figure 4:  

VAVS-O, VAVS, VAV & VVTS series components 

Содержание ECL-103

Страница 1: ...ure during shipping storage to evaporate Upon unpacking the product inspect the contents of the carton for shipping damages Do not install damaged controllers Avoid areas where corroding deteriorating...

Страница 2: ...3 wire voltage and current inputs and outputs as well as triac outputs should be kept apart from other types of wiring to avoid any ambient noise transmission to other wires The board connectors accep...

Страница 3: ...urn the controller s shaft coupler until it touches the mechanical end stop to either the fully closed position 90 boxes or the fully open position 45 and 60 boxes 6 For 90 VAV boxes If the damper clo...

Страница 4: ...wires when daisy chaining devices Use a wire nut with a pig tail to make such a connection Use an external fuse on the 24VAC side secondary side of the transformer as shown in Figure 8 to protect all...

Страница 5: ...COM To Analog To Digital Converter Potentiometer 10k 0 to 20mA input used with a 2 wire 0 to 20mA sensor powered by the controller s internal 15VDC power supply Sensor 0 20mA UIx COM 15VDC To Control...

Страница 6: ...UOx COM Linear 0 to 10VDC digital to analog output UOx 0 10V Common From Digital To Analog Output UOx COM 0 to 10VDC voltage output controlling an analog actuator that is powered by an external 24VAC...

Страница 7: ...network topology and wire length restrictions refer to the Network Guide It can be downloaded from our website It is important to use proper network terminators depending on the type of network topolo...

Страница 8: ...evices are not to be thrown away in municipal waste Products must be disposed of at the end of their useful life according to local regulations and the WEEE Directive North American Emissions Complian...

Страница 9: ...Heating Floating Actuator LONWORKS Network Back of Allure EC Smart Vue Wireless Port beneath cover E D E D Service PIN Button BAC LON Figure 14 Typical Power and Network Connections with an Allure EC...

Страница 10: ...rcuit shows approximately 0V DC and an open circuit shows approximately 5V DC Configuration problem Using EC gfxProgram check the configuration of the input Refer to the controller s user guide for mo...

Страница 11: ...eats every 2 seconds highest priority shown first Long blink continuous 1s On 1s Off continuous The controller is unconfigured Appropriate action Commission the controller Long Long Long blink 800ms O...

Страница 12: ...VAC specialist installers and are responsible for using the correct wiring procedures and maintaining safe working conditions with fail safe environments Distech Controls reserves the right to change...