The LYNK II Communication Gateway unlocks the full potential of a Discover
Lithium battery by enabling the internal Battery Management System (BMS) to
provide real-time data in a closed-loop configuration to other devices. In solar
applications, this allows the world’s best hybrid inverter-chargers and solar charge
controller systems to optimize their control over the charging process. LYNK II also
enables the remote monitoring of Discover Lithium battery SoC and data logging
of multiple sites using the data monitoring services offered by off-grid inverter
systems.
Discover Lithium batteries must be set up to work with power conversion and
monitoring devices in either an open-loop or closed-loop configuration.
Discover Lithium battery charge, and discharge settings in an open-loop
configuration are set up manually through the controller for the power conversion
device at the time of installation. An open-loop configuration is commonly
referred to as a ‘lead-acid drop-in’ replacement configuration.
In a closed-loop configuration, the BMS of the Discover Lithium battery sends
battery status over a network data connection with the power conversion device.
Power conversion devices use the Discover Lithium battery BMS data to finetune
the output of their charger and deliver other functional controls based on battery
voltage, temperature and percent State-of-Charge.