2-10 CHANNEL 4 VALIDITY/LATCHED/LATCHED RESET WITH IGNITION/30 SECOND TIMED/90 SECOND TIMED
OUTPUT:
This wire provides a (-) 200mA output whenever the transmitter button(s) controlling Channel 4 is
pressed. This output can be programmed to provide the following types of outputs (see also the
Feature Menus
section):
■
Validity:
Output that will send a signal as long as the transmission is received.
■
Latched:
Output that will send a signal when the Channel 4 button(s) is pressed and will continue until the
same button(s) is pressed again.
■
Latched, reset with ignition:
Similar to the latched output, this type of output turns on the first time the
Channel 4 button(s) is pressed and turns off the next time the same button is pressed. This type of output
additionally stops and resets whenever the ignition is turned on and then off.
■
30-second timed:
Output that will send a continuous signal for 30 seconds.
■
90-second timed:
Output that will send a continuous signal for 90 seconds.
2-11 CHANNEL 5 VALIDITY/LATCHED/LATCHED RESET WITH IGNITION/30 SECOND TIMED/90 SECOND TIMED
OUTPUT:
Channel Four can be programmed for these output configurations. The unit is set to the default valid-
ity output. To change the configuration, use the two-chirp setting to toggle through the different configurations.
Refer to channel 4 feature 2-10 for additional detail.
3-1 ENGINE CHECKING ON/OFF:
In the default setting the remote start will monitor either the vehicle's tach
wire or voltage depending on the programming of feature 3-2. If programmed OFF the vehicle will crank for the
programmed crank time (feature 3-5) and will not verify with tach or voltage that the car is running. In the OFF
setting, if the vehicle fails to start, the ignition can stay on for the entire run duration. Using tach or voltage
check is always recommended if possible.
3-2 CHECKING TYPE TACH/VOLTAGE:
Selects the method of engine monitoring. If set to TACHOMETER the unit
will reference the learned tach signal to disengage the starter. In addition it will monitor the RPM and shut down
if the engine RPM is too high or too low. When set to VOLTAGE, the unit will crank the starter for the programmed
time and then attempt to sense that the engine is running by detecting an increase in voltage. The threshold for
the voltage check is selectable in feature 3-6.
3-3 RUN TIME 12, 24, 60 MINUTES:
Selects the time in minutes that the system will operate the engine
until the system "times out". This is the maximum operation period and the system may be shut down
using a shutdown at any time. Using the Bitwriter, the run time can be programmed for any duration from 1-60
minutes.
menu #3 - remote start options