15-min Timer

- The 15-minute remote timer is typically installed in areas

where contaminated such as moisture and odors, are produced. Simply push
the button and the HRV will activate to high speed for 15 minutes. Up to 5
electronic timers can be installed throughout the building at a distance of up
to 500 feet (152 meters) from the HRV.

Dehumidistat II 

- The wall mount dehumidistat II offers the same features of

the dehumidistat I plus additional off/on control for the HRV. Dial illuminates
when in override mode.

RTS 3

- The RTS 3 is designed to provide an intermittent boost to the Heat/Energy

recovery ventilator.  Depressing the fan control button will energize the HRV/ERV
system into high speed from a low or standby mode.  The ventilator can be set to
continue on high for 20, 40, or 60 minutes by pressing the control button one, two
or three times.  Pressing the button a fourth time will cancel the timing function.

EDF 1

- The EDF 1 is designed to provide 3 modes of operation to the Heat/Energy

recovery ventilator.  Pressing the “Push” button once initiates the unit to run at a
continuous low speed of operation (green). Depressing the button twice allows the
ventilator to run for 20 minutes and then turns off for 40 minutes (yellow).  Touch
the button a third time and the system will run continuous on high (red).  The ven-
tilation system will stay on the last function selected until it is changed.

Dehumidistat I

- The wall mount dehumidistat monitors the humidity level in

the area it is installed. When the humidity level rises above the desired set-
point, the HRV will activate to high speed/override mode. Once the humidity
level returns to desired condition, the unit will return to the normal mode. 

To avoid window condensation: 
• It is not necessary to

change the humidity control
every day. Monitor the
average weekly
temperature or experiment
with various settings until
you find a level that is
comfortable for you. Adjust
the control when needed.

PRACTICAL
TIPS

* All controls are low voltage. 18 to 24

gauge wire is recommended.

OPTIONAL REMOTE CONTROLS

OPERATION

(CONT'D)

NOTE:

A dehumidistat is ideal for
use in energy efficient
houses where indoor
humidity (during the
heating season) is higher
than outdoor levels. High
humidity is a major cause
of structure damage and
IAQ problems such as mold
and mildew.

2 wire

installation

4 wire

installation

3 wire

installation

2 wire

installation

2 wire

installation

5MR

INTELLITEK
MULTI-FUNCTION
WALL CONTROL

Control multiple func-
tions of your
Powrmatic HRV with
one slimline wall con-
trol. Two wire connec-
tion simplifies installa-
tion. Use one EDF5 per
PHRVR installed.

OVERRIDE SPEED
CONTROL

Push to select
override speed of
unit.

CYCLE CONTROL

Set unit to cycle on
15, 20, or 30 min-
utes every hour

MODE SPEED

Set Unit to Low,
Medium or High
Speed

OVERRIDE TIMER

When pressed, unit 
will provide high
speed 

ventilation

for one 15, 
30 or 60 minute
period.

DIGITAL DISPLAY 

Shows Indoor Humidity Level
This control will not read
below 29% RH

DEHUMIDISTAT CONTROL

(see description on top of this page) 

MAINTENANCE LIGHT

Light comes on when
it’s time to clean
unit.

POWER

On/Off and Reset

MODES

Select Intermittent,
Recirculation or
Continuous
Ventilation Modes 

OPTIONAL INTELLITEK CONTROL

NOTE:

When an Intellitek control
is installed, the rocker
switch located on the right
hand side of the HRV will
be automatically
deactivated giving the user
complete control from
wherever he/she wishes to
mount the control pad.

NOTE:

The override speed cannot
be set at a fan speed lower
or equal to the normal
operating fan speed.  For
example, if the unit is
normally operating at a
medium fan speed, the
override fan speed will be
automatically set to high.

NOTE:

5MR model, changing the
override speed will change
default override speed for
other external controls.

EXAMPLES:

If on the 5MR control, you
have set the override
control at  medium, and
you start an external
remote control (15 min.
timer), the unit will run at
medium speed for 15 min.

PRACTICAL
TIPS

4 1/2"

(114 mm)

Width = 4 1/2" (110mm)

Height = 5 1/8" (130mm)

Thickness = 5/8" (15mm)

5 1/8"

(130 mm)

Содержание PHRV

Страница 1: ...PHRV Heat Recovery Ventilator INSTALLATION OPERATION AND MAINTENANCE MANUAL ...

Страница 2: ...des in effect in his area The warranty is limited to 5 years on parts and 7 years on the motor from the date of purchase including parts replaced during this time period If there is no proof of purchase available the date associated with the serial number will be used for the beginning of the warranty period This warranty is the exclusive and only warranty in effect relative to the ventilation sys...

Страница 3: ...d ebm motors with backward curved blades Motors come with permanently lubricated sealed ball bearings to guarantee long life and maintenance free operation Seven 7 year warranty Steep fan curves requires no balancing of airflows CORE Aluminum heat recovery core configured for efficient cross flow ventilation Core is 8 5 x 8 5 216 x 216 mm with a 8 205 mm depth Cores are manufactured by Fantech to ...

Страница 4: ...ower cord w 3 prong plug Continuous ventilation mode of supply and exhaust airstreams 10 254mm of clear ance is recommended for removal of core Pa in wg L s cfm L s cfm L s cfm 25 0 1 45 96 47 99 49 104 50 0 2 40 85 41 88 41 88 75 0 3 32 67 33 69 34 72 100 0 4 26 56 27 58 28 58 125 0 5 20 42 20 43 20 43 EXT STATIC PRESSURE NET SUPPLY AIR FLOW GROSS AIR FLOW SUPPLY EXHAUST C F L s cfm Heating 0 32 ...

Страница 5: ...p should be made in the drain line This will prevent odors from being drawn back up into the unit MOUNTING EASY WALL MOUNT LOCATION The HRV must be located in a heated space where it will be possible to conveniently service the unit Typically the HRV would be located in the mechanical room or an area close to the outside wall where the weatherhoods will be mounted If a basement area is not conveni...

Страница 6: ...and not be compressed The outer liner which acts as a vapor bar rier must be completely sealed to outer wall and the HRV using tape and or caulking A good bead of high quality caulking preferably acoustical sealant will seal the inner flexible duct to both the HRV port and the weatherhood prior to clamping To minimize air flow restriction the flexible insulated duct that connects the two outside w...

Страница 7: ...ed ducting from the HRV ERV to the living areas in the house is recommended whenever possible although flexible duct can be used in moderation when necessary Warning The PHRV96 should be installed with a 4 100mm duct system that has less than 80 ft 25m of equivalent duct length on the supply and on the exhaust side If longer runs are required increasing the duct diameter or following the instructi...

Страница 8: ...n may change depending on model Fully Dedicated System suggested for new construction Stale air drawn from key areas of home bathroom kitchen laundry Fresh air supplied to main living areas NOTE PHRV96 should be mounted with its duct connec tions on top or similar ...

Страница 9: ...ent it is being connected to the HRV ERV s airflow should be confirmed on site using the balancing procedure found in the installation manual If a release is required due to the furnace pulling too much air from the HRV ERV special care and attention is needed to its design DIRECT CONNECTION of the SUPPLY AIR STREAM to the FURNACE COLD AIR RETURN Stale air drawn from key areas of home Building Cod...

Страница 10: ... Air Out damper until you reach the desired velocity Follow the previous steps to adjust the Exhaust Air Out damper if needed B Measure here Measure here 12 300 mm 12 300 mm To avoid airflow turbulence and incorrect readings the airflow velocity should be measured on steel ducting a minimum of 12 300 mm from the unit or elbow and before any transition AIRFLOW STATION GRID METHOD Fantech s superior...

Страница 11: ... Every 3 6 Months Unplug unit before doing any repairs or maintenance a Open access door b Carefully grip handle of core and pull out Core will slide out of the channel c Once removed from the cabinet remove filters d Wash core in warm soapy water do not use dishwasher e Install clean core by a First mounting the bottom flange of the core guide into the bottom channel approximately 1 4 6mm b Mount...

Страница 12: ...control board which offers a wide variety of features making it the ultimate ventilation control system Powrmatic engineers have used the latest technology to provide solid trouble free operation under any conditions The Powrmatic uni control board offers stand alone operating capabilities as well as an exclusive 2 wire communication to most external controls The trouble free optional controls inc...

Страница 13: ...he control when needed PRACTICAL TIPS All controls are low voltage 18 to 24 gauge wire is recommended OPTIONAL REMOTE CONTROLS OPERATION CONT D NOTE A dehumidistat is ideal for use in energy efficient houses where indoor humidity during the heating season is higher than outdoor levels High humidity is a major cause of structure damage and IAQ problems such as mold and mildew 2 wire installation 4 ...

Страница 14: ...RV Locate the grilles high on the walls or under the baseboards install ceiling mounted diffuser or grilles so as not to directly spill the supply air on the occupant eg Over a sofa Turn down the HRV supply speed A small duct heater 1kw could be used to temper the supply air Placement of furniture or closed doors is restricting the movement of air in the home If supply air is ducted into furnace r...

Страница 15: ...timer up to 5 timers Dehumidistat 2 wires Dehumidistat On Off 4 wires Mechanical Crank Timer 2 wires and or and or 1 only Air Quality Sensor CUR SW DEHUM N C N O TIMER EDF COM FURNACE INTERLOCK IN COM EDF5 or EDF2 not shown EDF1 RTS3 observe plarity Wiring diagram of complete unit inside of access panel 2 wires 2 wires 3 wires ...

Страница 16: ... the furnace has the effect of energizing Y at the thermostat and thereby turning on the cooling system If you identify this type of thermostat you must use the Alternate Furnace Interlock Wiring PRACTICAL TIPS ELECTRICAL CONNEC TION TO A FURNACE Standard Accessory Control Contact Alternate Accessory Control Contact Item 403322 Rev Date 030806 Montréal 9500 BLVD Ray Lawson Anjou QC H1J 1L1 T 514 4...

Отзывы: