PHRV96

Compact top port design HRV with easy-mount wall bracket.
Brings a continuous supply of fresh air into a home while
exhausting an equal amount of contaminated air. HRVs use
what is called a “sensible” heat recovery core. This special
core transfers heat from the exhaust air stream to the
incoming air stream. Fresh incoming air is tempered by the
heat that is transferred from the outgoing air to save on
energy costs. The PHRV96 is equipped with automatic
defrost mechanisms so even if you live in the coldest cli-
mates you can use your HRV all year long.

FEATURES

• Super Compact Size
• Top Port Design Fits in Tight Spaces
• Includes Easy-Mount Wall Bracket
• Aluminum Heat Recovery Core
• 4” (100mm) Duct Connections
• No Balancing Required
• Easy Access Service Door
• 3’ (914mm) Plug-in Power Cord
• Automatic Exhaust Defrost Allows Units 

to Always Stay in Ventilation Mode 

• Only 26 lbs (12 kg)
• Electrostatic Filters (washable)
• Easy Core Guide Channels For Removing Core
• Multiple Speed Operation

ACCESSORIES

• EDF1

– Multi-function 

control 

• RTS3 

– 

20/40/60 minute over-ride

• RTS2 

15 minute over-ride

• COM 4P 

– 

4˝ Weather Hoods 

(1 supply & 1 exhaust)

• FEL 4

– 

4˝ 90˚ Elbow

• CG 4 

4˝ Adjustable Grille

SPECIFICATIONS

CASE

24 gauge galvanized steel. Baked powder coated paint,

grey. Cabinet fully insulated with 1" (25 mm) aluminum foil-
face high density polystyrene foam to prevent condensation
and meet the requirements of the UL 94HF.

MOTORS

Two (2) German-manufactured, factory-balanced

ebm™ motors with backward curved blades. Motors come
with permanently lubricated sealed ball bearings to
guarantee long life and maintenance-free operation. Seven
(7) year warranty. Steep fan curves requires no balancing of
airflows.

CORE

Aluminum heat recovery core configured for efficient

cross-flow ventilation. Core is 8.5˝ x 8.5˝ (216 x 216 mm)
with a 8˝ (205 mm) depth. Cores are manufactured by
Fantech to withstand extreme temperature variations.

FILTERS

Two (2) Washable Electrostatic Panel Type Air Filters,

8.5˝ (216mm) x 8˝ (203mm) x 0.125˝ (3mm).

CONTROLS

Unit is designed to accommodate the whole

series of Fantech HRV controls.

DEFROST

A preset 5 minute defrost sequence is activated at

an outdoor air temperature of 23°F (-5°C) and lower. During
the defrost sequence, the supply blower shuts down & the
exhaust blower switches into high speed to maximize the
effectiveness of the defrost strategy. The unit then returns
to normal operation for 25 minutes, and continues cycle.

SERVICEABILITY

Core, filters, motors and drain pan can be

easily accessed through latched door. Core conveniently
slides out on our new easy glide core guides. 10˝ (250mm)
of clearance is recommended for removal of core.

DUCT CONNECTION

4˝ (100mm) steel duct connections with

rubber gasket for easy sealing.

DRAIN

1/2˝ (13mm) OD (outside diameter) drain spout

provided, entire bottom of unit covered by pan.

WARRANTY

Limited lifetime on aluminum core, 7 year on

motors, and 5 year on parts.

Distributed by:

Fantech, reserves the right to modify, at any time and without notice, any or all of its products’ features,
designs, components and specifications to maintain their technological leadership position.

Содержание PHRV

Страница 1: ...PHRV Heat Recovery Ventilator INSTALLATION OPERATION AND MAINTENANCE MANUAL ...

Страница 2: ...des in effect in his area The warranty is limited to 5 years on parts and 7 years on the motor from the date of purchase including parts replaced during this time period If there is no proof of purchase available the date associated with the serial number will be used for the beginning of the warranty period This warranty is the exclusive and only warranty in effect relative to the ventilation sys...

Страница 3: ...d ebm motors with backward curved blades Motors come with permanently lubricated sealed ball bearings to guarantee long life and maintenance free operation Seven 7 year warranty Steep fan curves requires no balancing of airflows CORE Aluminum heat recovery core configured for efficient cross flow ventilation Core is 8 5 x 8 5 216 x 216 mm with a 8 205 mm depth Cores are manufactured by Fantech to ...

Страница 4: ...ower cord w 3 prong plug Continuous ventilation mode of supply and exhaust airstreams 10 254mm of clear ance is recommended for removal of core Pa in wg L s cfm L s cfm L s cfm 25 0 1 45 96 47 99 49 104 50 0 2 40 85 41 88 41 88 75 0 3 32 67 33 69 34 72 100 0 4 26 56 27 58 28 58 125 0 5 20 42 20 43 20 43 EXT STATIC PRESSURE NET SUPPLY AIR FLOW GROSS AIR FLOW SUPPLY EXHAUST C F L s cfm Heating 0 32 ...

Страница 5: ...p should be made in the drain line This will prevent odors from being drawn back up into the unit MOUNTING EASY WALL MOUNT LOCATION The HRV must be located in a heated space where it will be possible to conveniently service the unit Typically the HRV would be located in the mechanical room or an area close to the outside wall where the weatherhoods will be mounted If a basement area is not conveni...

Страница 6: ...and not be compressed The outer liner which acts as a vapor bar rier must be completely sealed to outer wall and the HRV using tape and or caulking A good bead of high quality caulking preferably acoustical sealant will seal the inner flexible duct to both the HRV port and the weatherhood prior to clamping To minimize air flow restriction the flexible insulated duct that connects the two outside w...

Страница 7: ...ed ducting from the HRV ERV to the living areas in the house is recommended whenever possible although flexible duct can be used in moderation when necessary Warning The PHRV96 should be installed with a 4 100mm duct system that has less than 80 ft 25m of equivalent duct length on the supply and on the exhaust side If longer runs are required increasing the duct diameter or following the instructi...

Страница 8: ...n may change depending on model Fully Dedicated System suggested for new construction Stale air drawn from key areas of home bathroom kitchen laundry Fresh air supplied to main living areas NOTE PHRV96 should be mounted with its duct connec tions on top or similar ...

Страница 9: ...ent it is being connected to the HRV ERV s airflow should be confirmed on site using the balancing procedure found in the installation manual If a release is required due to the furnace pulling too much air from the HRV ERV special care and attention is needed to its design DIRECT CONNECTION of the SUPPLY AIR STREAM to the FURNACE COLD AIR RETURN Stale air drawn from key areas of home Building Cod...

Страница 10: ... Air Out damper until you reach the desired velocity Follow the previous steps to adjust the Exhaust Air Out damper if needed B Measure here Measure here 12 300 mm 12 300 mm To avoid airflow turbulence and incorrect readings the airflow velocity should be measured on steel ducting a minimum of 12 300 mm from the unit or elbow and before any transition AIRFLOW STATION GRID METHOD Fantech s superior...

Страница 11: ... Every 3 6 Months Unplug unit before doing any repairs or maintenance a Open access door b Carefully grip handle of core and pull out Core will slide out of the channel c Once removed from the cabinet remove filters d Wash core in warm soapy water do not use dishwasher e Install clean core by a First mounting the bottom flange of the core guide into the bottom channel approximately 1 4 6mm b Mount...

Страница 12: ...control board which offers a wide variety of features making it the ultimate ventilation control system Powrmatic engineers have used the latest technology to provide solid trouble free operation under any conditions The Powrmatic uni control board offers stand alone operating capabilities as well as an exclusive 2 wire communication to most external controls The trouble free optional controls inc...

Страница 13: ...he control when needed PRACTICAL TIPS All controls are low voltage 18 to 24 gauge wire is recommended OPTIONAL REMOTE CONTROLS OPERATION CONT D NOTE A dehumidistat is ideal for use in energy efficient houses where indoor humidity during the heating season is higher than outdoor levels High humidity is a major cause of structure damage and IAQ problems such as mold and mildew 2 wire installation 4 ...

Страница 14: ...RV Locate the grilles high on the walls or under the baseboards install ceiling mounted diffuser or grilles so as not to directly spill the supply air on the occupant eg Over a sofa Turn down the HRV supply speed A small duct heater 1kw could be used to temper the supply air Placement of furniture or closed doors is restricting the movement of air in the home If supply air is ducted into furnace r...

Страница 15: ...timer up to 5 timers Dehumidistat 2 wires Dehumidistat On Off 4 wires Mechanical Crank Timer 2 wires and or and or 1 only Air Quality Sensor CUR SW DEHUM N C N O TIMER EDF COM FURNACE INTERLOCK IN COM EDF5 or EDF2 not shown EDF1 RTS3 observe plarity Wiring diagram of complete unit inside of access panel 2 wires 2 wires 3 wires ...

Страница 16: ... the furnace has the effect of energizing Y at the thermostat and thereby turning on the cooling system If you identify this type of thermostat you must use the Alternate Furnace Interlock Wiring PRACTICAL TIPS ELECTRICAL CONNEC TION TO A FURNACE Standard Accessory Control Contact Alternate Accessory Control Contact Item 403322 Rev Date 030806 Montréal 9500 BLVD Ray Lawson Anjou QC H1J 1L1 T 514 4...

Отзывы: