![Dini Argeo TPW E-FORCE Скачать руководство пользователя страница 86](http://html1.mh-extra.com/html/dini-argeo/tpw-e-force/tpw-e-force_user-and-maintenance-instructions_2505727086.webp)
TPW
86
Troubleshooting cases
USER_MAN_ENG_TPWE-FORCE
The weight is
unstable
•
Check whether the weighing filter is active
.
•
If the support surface is subjected to vibrations from machinery or mov-
ing vehicles, move the scale onto another surface and try again.
PIECE COUNTER
The scale does
not carry out
sampling
•
The weight is unstable (
Err.Mot
)
•
The weight is insufficient, add more pieces and try again (
Error
)
CARPENTRY AND
TRACTION TILLER
The machine does
not start
•
Low battery
•
Burned fuse
•
Broken key
•
Electrical system short circuit
•
Damaged traction control board
•
Damaged user interface board
The forks do not rise
•
The lever is not in position B - Raising
•
Valve sphere does not close
•
Adjustment screw displaced
•
Piston seals worn or damaged
•
There is no oil in the tank
The forklift does not
brake
•
Low braking torque
The battery does not
charge
•
The battery is not connected to the charger
•
The key is not inserted in the battery
•
The charger is not connected correctly
•
Battery charger fuse broken
The forks do not
remain raised
•
Worn cylinder seals
•
Dirty pressure valve