Operator’s Manual
Function Tests
GTWY1200 SERIES 12
Setup
1. Position the machine on a firm surface
directly below the desired work area.
2. Connect to the appropriate power source:
DC models: Connect the battery pack. AC
models: Connect to a grounded 15A AC
power supply. Use a 12 gauge / 3.3mm
2
3-wire grounded extension cord no longer
than 50 feet / 13 m.
Result: The power light should come on.
3. Turn on the circuit breaker.
4. Insert the key and turn to ground control or
platform control.
5. Twist the red Emergency Stop buttons to
the on position both at the ground and the
platform controls.
6. Pull the outrigger lock pin up, turn an
outrigger out until the outrigger lock pin
snaps into place. Adjust the outrigger to
level the machine and raise the base
casters slightly off the ground. Level the
machine using only the outriggers.
7. Check the interlock display lights at the
ground controls. Confirm that the
corresponding light is on.
8. Repeat
this
procedure for each of the
remaining outriggers.
9. Use the bubble level and adjust the
leveling jacks until the machine base is
level.
Test Emergency Stop
10. Push in the red Emergency Stop button at
the ground controls to the off position.
11. Push in the up/down switch at ground
control in the direction of intended travel.
(Turn the key switch to ground control)
Result: The up/down function should not
operate
12. Push in the control activate button and
rotate the up/down switch at the platform
in the direction of intended travel. (Turn
the key switch to platform control)
Result: The up/down function should not
operate
13. Push in the red Emergency Stop button at
the platform controls to the off position.
14. Twist the red Emergency Stop button at
the ground controls to the on position.
15. Push in the up/down switch at ground
control in the direction of intended travel.
(Turn the key switch to ground control)
Result: The up/down function should not
operate
16. Push in the control activate button and
rotate the up/down switch at the platform
in the direction of intended travel. (Turn
the key switch to platform control)
Result: The up/down function should not
operate