EN-18
6.1
English
Sets the preparation of swimming pool water
Swimming pool
Sets the external temperature below which
domestic hot water preparation is carried out
with 2 compressors in 2-compressor heat
pumps
-30 °C
...
25 °C
...
-35 °C
(10 °C HT)
Swimming pool
2 compressors
In parallel operation, the maximum number of
compressors available in the network is
displayed here. The number of these that are to
be used for swimming pool water preparation
can be selected.
...
0
...
28
Swimming pool
Paralell connection
Master controller
Sets the desired swimming pool temperature
5 °C
...
25 °C
...
60 °C
Swimming pool
Reversible HP
Sensor
Sets the desired swimming pool temperature
with parallel cooling operation
5 °C
...
25 °C
...
60 °C
Swimming pool
Reversible HP
Additional heat
exchanger
Sensor
The hysteresis of the swimming pool set
temperature forms the neutral zone below
which a swimming pool request will be issued.
0K
...
0,5+K
...
20K
Swimming pool
Reversible HP
Sensor
Sets whether the waste heat recovery during
cooling is dependent on the switching status of
the thermostat or in continuous operation
No
Yes
Swimming pool
Reversible HP
Additional heat
exchanger
Sets the time programs for blocking swimming
pool water preparation
Swimming pool
Sets the times at which a swimming pool block
is to take place
00:00
...
23:59
Swimming pool
For each day of the week, it is possible to select
whether Time1, Time2, no time or both times
are to be active for a swimming pool block.
Blocks that exceed a weekday are activated or
deactivated at the end of each day accordingly.
N
T1
T2
Y
Swimming pool
Sets the time programs for a priority of
swimming pool water preparation
Swimming pool
Sets the start time for the swimming pool
priority
00:00
...
23:59
Swimming pool
Sets the desired number of hours for which
swimming pool priority should be given
1
...
10
Swimming pool
For each day of the week, it is possible to select
whether a priority is desired at the set start
time.
N
Y
Swimming pool
The output of the auxiliary circulating pump can
be configured to allow parallel operation of the
auxiliary circulating pump and the heat pump's
compressor. Configuration is possible for
heating, domestic hot water preparation and
swimming pool water preparation. Frost
protection functions are ensured.
Always
Should the auxiliary pump operate during
heating operation?
No
Yes
Heating circuit 1
System-specific parameters
Setting range
Display
Содержание WPM EconPlus
Страница 4: ......
Страница 44: ...DE 40 Deutsch 13 5...
Страница 82: ...EN 38 13 5 English...
Страница 124: ...FR 42 13 5 Fran ais...
Страница 142: ...A XVIII Anhang Appendix Annexes 4...
Страница 143: ...A XIX Anhang Appendix Annexes Diagnose St rungen Alarm Troubleshooting Alarms Diagnostic d fauts alarmes 4...