EN-10 EF12_20_gb · 12/14/B
www.dimplex.de/en
E
n
g
lis
h
EF 12/20, EF 12/20 TI, EF 12/20 TID, EF 12/10
5.3 EF 12/20 TID - Models with 24-hour timer
The operating hours of the heater can be set in a day
program (24 hours) using the timer.
For automatic operation, slide the switch (C) to the right
into "clock" position.
Setting the time:
Turn timer (D) clockwise until the marking matches up
to the current time.
Heater ON: Slide segments outwards.
Heater OFF: Slide segments inwards.
Each segment represents a switch-on or switch-off
time of 20 minutes. In order, for example, to set a
switch-on time of one hour, 3 segments are slid out-
wards.
The timer can be pro-
grammed for several ON/
OFF phases of different
lengths. The thermostat
provides a uniform room
temperature during the
switch-on time.
Outside of the switching
time, no heating opera-
tion - and thus no frost
protection - takes place.
Operation via the timer can be deactivated at any time
by switching to "Manual" or "0" (OFF).
The timer only runs when the device is connected to
the power supply.
6. Protection Against Overheating
If the permissible temperature is exceeded, the heater
switches off automatically. If this occurs, pull the mains
plug out and leave the device unplugged for a few min-
utes, so that the temperature limiter can switch back
again.
Then remove the cause, e.g. when the air grid is
blocked or covered. When the device has cooled suffi-
ciently, it can be started up again.
7. Faults
If the heater does not give off heat, check the fol-
lowing points:
Has the thermostat been set to the desired temper-
ature?
Has the overheat protection been triggered? See
chapter 6!
Is the fuse in the fuse box switched on?
EF 12/20TI: Is the timer knob set to OFF?
EF 12/20 TID: Set the slide switch and segments
correctly - see Chapter 5.3 "Heating Operation EF
12/20 TID"!
Glen Dimplex Deutschland GmbH
Am Goldenen Feld 18
D-95326 Kulmbach
Subject to modifications
If the fault cannot be corrected, please contact a spe-
cialist electrical service center or else your nearest
after-sales service.
To process your order, please state the production
number (E No.) and manufacturing date (FD) of the de-
vice. This information is listed on the type plate.
The device must only be repaired or manipulated by a
skilled electrician or the after-sales service.
8. Cleaning
To clean the device, first disconnect it from the mains
and allow it to cool down. Clean the outside of the unit
using a soft, damp cloth. Do not use scouring powder
or furniture polish as this may damage the surface.
Dust which gathers inside the device can be removed
from the outside using a vacuum cleaner.
9. Warranty
Please contact your local dealer for information on cus-
tomer service and warranty conditions.
10. Note on Disposal
Do not dispose of the unit with general house-
hold waste. The device must be taken to a local
waste disposal plant.