P750LV2.1 industrial gate motor manual
8
Factory setting
Timer
F/Setting
Step
Setting Method
Range
Open Cycle Time
60sec.
0.1sec
SET1 on + OPN Button
0-6550sec.
Close Cycle Time
60sec.
0.1sec.
SET1 on + CLS Button
0-6550sec.
Ped Cycle Time
10sec.
0.1sec.
SET1 on + PED Button
0-6550sec.
Sync Delay Time
2sec.
0.1sec.
SET1 on + STP Button
0-25sec.
Auto Close Time
30sec.
0.1sec.
SET1 on + OSC Button
0-6550sec.
PE Auto close Time
2sec.
0.1sec.
SET1 on + PEB Button
0-25sec.
Warning time
3sec
0.1sec
SET2 on + OPN Button
0-25sec
Lock Pulse Time
1sec.
0.1sec
SET2 on + CLS Button
0-25sec
Light Time
60sec
0.1sec
SET2 on + PED Button
0-6550sec
Motor Stop Time
0.5sec
0.1sec
SET2 on + PED Button
0-25sec
Two-T1 Time(spare)
60sec
0.1sec
DIP2 on + OSC Button
0-6500sec
Two-T2 Time(spare)
60sec
0.1sec
DIP2 on + PEB Button
0-6500sec
To restore factory setting, turn power off and set SET1 on, push and hold CLS
button, then power on. While hold CLS button, set SET1 off and then release the
CLS button. Now controller restored factory setting from memory.
3. Light output
With the additional module, which plugs into the control board, the control board will control
light, which will illuminate the driveway etc. The light will automatically turn off after preset time
(customer programmable). If DIP4 is set to ON, the M2 output will change to light output.
4. Audio warn output
On Board buzzer can give warn for diagnose. Additional buzzer or relay module, which plugs into the
control board, the control board give out audio warning signals before gate moves
If PB beam is blocked or Stop input is not shorted, four short bee will be heard
5. Inverter settings
Different inverter and setting are different. P750V5.0 can control nearly all model inverter. 12V or 24V
accessories power supply. PNP or NPN output. Here is some samples.
a)
TECO FM 50 inverter. 12V, PNP output, now it is no longer
available.
Function
F
Function Description
Setting Unit Note
Acceleration time
F001
Acceleration time
4.0
Sec.
Deceleration time
F002
Deceleration time
2.0
Sec.
Freq. Upper limit
F006
Max. Frequency
60
Hz
Freq. Lower limit
F007
Min. Frequency
0
Hz
SP1 Frequency
F008
Gate Close High Speed
35
Hz
Start/Stop/Control
F010
Terminals
1
Multifunction Input
F020
Reset Terminal Function
6
SP2 Frequency
F026
Gate Open Low Speed
15
Hz
SP3 Frequency
F027
Gate Close Low Speed
15
Hz