7.4.5.2. The output of the actual position
The CamCon offers the possibility to put the physical
actual position out to outputs. It is used when several
CamCon need the same actual position (Master Slave
connection). To be able to use this option, the number of
the programmed outputs has to be lower than the number
of the actually available ones (see chapter "7.4.6.2.
Setting the outputs" on page 63. The output of the bit with
the lowest value will occur after the last programmed
output. The other bits follow in increasing order.
With the
and
keys you can choose 4 possible output formats:
"No"
=
No output of the actual position.
"Gray"
=
Output of the actual position in the gray code.
"Bin."
=
Output of the actual position in the binary code.
"Exp."
=
Output of the actual position in the gray code only for CamCon DC115.
Confirm your input with the
key.
7.4.5.3. Direction output
To be able to recognize the direction of the movement of a
machine with different movement directions, you can
program an output that switches on at a positive and off at
a negative movement.
7.4.5.4. The standstill output
The CamCon offers the possibility of a standstill
surveilance. Here you can define an output that is
switched on when the actual speed is greater than the at
"
dir Hyst.
" entered value and that switches off when the
speed drops below that value again.
7.4.5.5. The hysteresis
To be able to use the options of movement direction surveilance and standstill surveilance correctly,
you have to set the hysteresis. This value is needed to suppress the jittering of the outputs at small
changes in speed. This value can only be determined through experiments, but it should be as small
as possible.