Digitronic
Digital Cam Switch Unit
Automationsanlagen GmbH
CamCon DC50/51
7.5.3.3. Analog outputs
The electronic cam controllers of the CamCon series are equipped with analog outputs (CamCon
DC40/50/51 optionally, CamCon DC115 as a standard), via which speed, position or the cam values
can be emitted as analog signals.
Note:
With units CamCon DC16, DC90 and DC300 you can only use the analog outputs by
connecting a CamCon DAC16 digital - analog - converter to the external interface.
7.5.3.3.1. Clearing the integrated analog outputs
At the time, units CamCon DC40/50/51 (optionally) and
CamCon DC115 (as a standard) are supplied with integrated
analog outputs. The outputs are cleared by setting their number
in the menu point
"Int.Anlg"
. The possible numbers are 0,1
and 2. A value of 0 deactivates the integrated outputs.
Note:
Not possible with CamCon DC16 and DC90.
If the value is greater than 0, a line for adjustments appears
below the menu point
"Int.Anlg"
.
7.5.3.3.2. Adjusting the integrated analog outputs
Note:
With units of increment DC51/S
5
.., DC51/J
5
.. or DC40/S
5
.. this feature is neither
necessary nor possible.
The integrated analog outputs of the CamCon have to be regulated from time to time and after the first
activation. Offset and amplification can be adjusted. The maximum analog output voltage is
±
10V with
a resolution of 8Bit. Should you wish for a smaller voltage range, you can edit the maximum voltage via
the amplification factor.
Offset output 1
Amplification factor output 1
With keys
and
you can set the amplification and the offset through repeated ajustments with
the keys and measuring the analog output voltage. From analog output 1 to analog output 2 and to
switch between offset and amplification factor, press keys
,
or
. When all 4 adjustments are
made, the input is ended with the
key and the menu is left.
See also chapters "7.4.5.6. The analog speed output" on page 61, chapter "7.3.17. Programming
analog cams" on page 43 and chapter "7.4.5.7. Configuration of the analog cams" on page 61.
7.5.3.3.3. External analog outputs
Additional external analog outputs can be connected to a CamCon through a CamCon DAC16 digital -
analog - converter module at the external interface.
,Version from: Aug. 04
Page: 72
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]
Site web : www.hvssystem.com