Digitronic
Digital Cam Switch Unit
Automationsanlagen GmbH
CamCon DC50/51
13. Technical data of the CamCon
Display .................................................graphical display with 128x64 pixels for user prompting and
programming (optional with background illumination)
Number of outputs ...............................8, 16, 24, 32 expandable up to 200 through the expansion bus
Number of inputs..................................8, 16 expandable up to 200 through the expansion bus.
Analog output .......................................2 optional analog outputs for the speed display or for the
programming through analog cams
Number of programmable cams ..........150, optionally 600, 2500, 3700 or 10500 cams
Data security/storage ...........................EEPROM
Number of programs............................32768
Cycle time ( switching speed ) .............from 0,1ms, is adjusted to the needs (optimized)
Dead time compensation (DTC) ..........individually adjustable for every output according to the
measuring system and the memory
Adjustment range of the DTC ..............0 to max. 9999.9ms according to the measuring system and
memory
Exactness of the DTC ..........................+0 to -1 step
Measuring system input .......................synchronous serial (SSI), gray coded, optional incremental data
input, optional parallel data input, analog data input, PLL data
input, time controlled data input
Resolution of the measuring system....360 steps (standard), otherwise adjustable according to
measuring system and memory
Measuring system SSI ........................AAG60007 (360 degree SSI standard type) AAG612-2048,
AAG612-4096,AAG612-8192, AAG626 oder AAG66107.
Border frequency
of the incremental input........................about 200kHz
Input level
of the incremental input........................5V RS244 or 24V PNP.
Zero point correction
of the measur. sys. ..............................is programmed by the CamCon
Rotation direction
of the measuring sys............................is programmed by the CamCon
Length of the connection cable
between the measuring system
and the CamCon..................................with SSI to max. 300m (optionally up to 1000m)
Supply voltage......................................24V DC
±
20 %
Measuring system supply voltage ........with 24V DC through the supply voltage of the CamCon
Current reception .................................300mA without measuring system and outputs
Output voltage......................................24V DC, plus switching
Output current ......................................500mA per output, short circuit proof permanent current (see
chapter 4.3. The outputs on page 24).
Connections for:
Measuring system ................................through plug block pins
Voltage supply......................................through plug block pins
Cam outputs.........................................through plug block pins
Operating temperature.........................0°C to +55°C
Cover type for:
Front plate / full sight gate....................IP 67 / IP 55
Cabinet.................................................IP 54
Dimensions ..........................................see fig. page 14
Front plate part.....................................138
+1
x 138
+1
mm
Cabinet:
Switch plate cabinet by DIN 43700 ......144 x 144 x 63mm (wxhxd)
Cover of the front plate ........................optional full sight gate, can be locked
Weight..................................................about 1000g
,Version from: Aug. 04
Page: 86
2 rue René Laennec 51500 Taissy France
Fax: 03 26 85 19 08, Tel : 03 26 82 49 29
E-mail:[email protected]