Figure 14 Home Page Reset Main Page to Defaults
Default vocoder values page are as follows:
Home Page Defaults Settings
Item
Value
Voice Source
4-Wire
Vocoder Mode
Full-Rate Vocoder
Target IP
127.0.0.1
Data Source
Loop-Back
Table 5 Home Page Defaults List
NOTE: At power-up the VCU automatically starts up with the default settings. You do not need to
use the web interface unless you want to change these settings.
Start and Stop Buttons
Upon power up the Net-2000™- P25 VCU loads the default settings and runs the half-rate decoder
in loopback over the 4-wire interface. Click the Stop button to put the Net-2000™- P25 VCU into idle
mode. In idle mode the VCU is not active and will not respond to voice or channel data packets.
Changes to the settings can be made while the unit is active. However, the new settings will not
take affect until the Start button is clicked.
Note: The “Start" button will automatically stop and restart the Net-2000™- P25 VCU. It is not
necessary to click on the “Stop" button and then click the Start button to restart the Net-2000™- P25
VCU with a new setting.
Figure 15 Start and Stop Buttons