Terminal Interface
4-27
4
Software Download Options
Immediate Software Activation (Enable/Disable)
The IMMEDIATE SOFTWARE ACTIVATION mode is controlled from the
SYSTEMS UTILITIES/SOFTEWARE DOWNLOAD MENU. When the
IMMEDIATE SOFTWARE ACTIVATION feature is enabled, the software
download (using MSR, Xmodem, Kermit, TFTP) is immediately activated
(that is, copied from RAM to FLASH and rebooted).
For consistency with the previous software version, IMMEDIATE=enabled
is the default setting. If the IMMEDIATE SOFTWARE ACTIVATION
feature is disabled, the software download (using MSR, Xmodem, Kermit,
TFTP) is not activated (that is, not copied from RAM to FLASH and not
rebooted).
The user must activate the software at a later time by issuing a software
download activation command from the System Utilities/Download
Software/ RAM SOFTWARE OPTIONS selection Þeld. When the software
activation command is executed, the system copies the software image
from RAM to Flash and reboots.
A system restart (power cycle) that occurs after the download, but before
the activation, will not activate the new software. Loss of power causes the
non-activated software download to be lost.
Download Destination (Local Unit, Remove Unit, Both Units)
This feature provides software to be loaded to either the local unit, the
remote unit, or both. The user must make sure the Þle being loaded
contains the software image compatible with the particular equipment type
for either end (that is, DL3800 versus DL3900). Use of the Remote or Both
option requires use of the Xmodem or Kermit protocol.
A Þle image loaded to the remote unit is sent over the proprietary
IMUX Embedded Data Link (EDL). The EDL is available regardless of
the T1 line coding and framing.
To download to the Remote Unit, the user does not log into the
Remote; instead the user selects the download destination using the
Download Destination Þeld which allows a download to both units at
once. It also minimizes disruption to the terminal interface session
when the Remote Unit does an immediate software activation (which
involves that unitÕs rebooting).
Содержание DL3800 DS1
Страница 1: ...DL3800 DS1 Inverse Multiplexer User Guide Part 098 10380 01 Rev J February 1999...
Страница 6: ...vi DL3800 DS1 Inverse Multiplexer User Guide February 1999...
Страница 12: ...Table of Contents xii...
Страница 22: ...xxii DL3800 DS1 Inverse Multiplexer User Guide February 1999...
Страница 26: ...1 4 DL3800 DS1 Inverse Multiplexer User Guide February 1999 1...
Страница 34: ...2 8 DL3800 DS1 Inverse Multiplexer User Guide February 1999 2...
Страница 128: ...C 4 DL3800 DS1 Inverse Multiplexer User Guide February 1999 C...