Front Panel Interface
5-25
5
The user can set the threshold value for Minor (MI) and Major (MJ) alarms,
where exceeding the Minor alarm threshold will generate an alarm report
and the exceeding a Major alarm threshold will actually cause a T1 line to
be automatically taken out of service.
Pressing the
ENTER
button when NET THRESHOLDS appears in the
display screen will start the menu and allow the user to scroll, using the
down or up arrow buttons, through the following options:
Table 5-6 NET THRESHOLD Options and Values
OPTION
VALUE
CON CRCS
010
CON CRCS
OFF
CON SES
010
CONSES ON
CON UAS
015
CON UAS
OFF
15.MIN.MI.BPV
100
15.MIN.MJ.BPV
100
15.MIN.MJ.BPV
OFF
15.MIN.MI.CRCS
100
15.MIN.MJ.CRCS
100
15.MIN.MJ.CRCS
OFF
15.MIN.MI.ES
100
15.MIN.MJ.ES
100
15.MIN.MJ.ES
OFF
15.MIN.MI.SES
100
15.MIN.MJ.SES
100
15.MIN.MJ.SES
OFF
15.MIN.MI.UAS
100
15.MIN.MJ.UAS
100
15.MIN.MJ.UAS
OFF
24.HR.MI.BPV
10
24.HR.MJ.BPV
10
24.HR.MJ.BPV
OFF