Terminal Interface
4-15
4
Unit Number
Move the Highlight bar to
Unit Number
, and enter a number between 0
and 9999. Note: Each unit must be set to a different number to allow
remote communication, and daisy chaining of multiple units. For example, if
the remote unit is set to the same number as the local unit, you will not be
able to access the remote unit.
Unit Name
Move the highlight bar to
Unit Name
, and press
Enter
.
Soft Serial Number
This feature allows the user to view the local serial number.
If the remote unit is not software compatible with the soft serial number
feature, the Unit Configuration screen still displays the serial number field
but the information is incorrect. All the other information on the screen (for
example, node number, hardware revision number) is still accurate.
The soft serial number is preserved if the user enters a “Reset Entire Node
Database to Factory Defaults” command.
Terminal Baud Rate
This feature selects the terminal baud rate. To set or change the baud rate,
move the highlight bar to
Terminal Baud Rate
, and press the Space Bar
to toggle between the options: 300, 600, 1200, 2400, 4800, 9600,
19,200, and 38,400. (Default - 9600)
Terminal Parity & Bits
This feature selects the terminal parity. To set or change the local terminal
parity, move the highlight bar to
Terminal Parity & Bits
, and press the
Space Bar to toggle between the options
None
,
Odd
, and
Even
. (Default -
None)
Terminal Stop Bits
This feature selects the terminal stop bit requirement. To set or change the
requirement, move the highlight bar to
Terminal Stop Bits
, and press
the Space Bar to toggle between the options
1
,
1.5
, or
2
. (Default - 2)
Terminal XOn/XOff
This allows the user to enable or disable the XOn/XOff Flow Control
feature. With the Flow Control feature On, the terminal can request that the
DTE quit sending data when its buffers are full. To set or change this feature,
move the highlight bar to
Terminal XOn/XOff
, and use the Space Bar to
select choice. (Default - On)
Terminal Multidrop Mode
If the terminal is connected to more than one DL3800, it must be in
Multidrop Mode. If it is connected to only one unit, this feature can be
disabled. When it is disabled, the system starts up directly, without the user
having to log in. To change this configuration, move the highlight bar to
Terminal Multidrop Mode
, and use the Space Bar to toggle between the
options
Enabled
, and
Disabled
. (Default - Enabled)
Table 4-5 Node Configuration Options (Continued)
Option
Action
Содержание DL3800 DS1
Страница 1: ...DL3800 DS1 Inverse Multiplexer User Guide Part 098 10380 01 Rev J February 1999...
Страница 6: ...vi DL3800 DS1 Inverse Multiplexer User Guide February 1999...
Страница 12: ...Table of Contents xii...
Страница 22: ...xxii DL3800 DS1 Inverse Multiplexer User Guide February 1999...
Страница 26: ...1 4 DL3800 DS1 Inverse Multiplexer User Guide February 1999 1...
Страница 34: ...2 8 DL3800 DS1 Inverse Multiplexer User Guide February 1999 2...
Страница 128: ...C 4 DL3800 DS1 Inverse Multiplexer User Guide February 1999 C...