Removing and Replacing FRUs
3–25
3.2.6 CRT/Chassis Assembly
Remove the CRT/chassis assembly as follows:
•
Remove the rear cover (Section 3.1.1).
•
Remove the top cover (Section 3.1.2).
•
Remove the deflection module (Section 3.2.2).
•
Remove the video casting assembly (Section 3.2.3).
WARNING
You must discharge voltage from the CRT (Section 3.2.4) before
removing the power supply module.
•
Remove the power supply module (Section 3.2.5).
3.3 CRT Disposal (Trained Service Personnel Only)
This section describes how to safely dispose of the monitor CRT. CRTs are
glass vacuum tubes. Because air pressure outside the tube is greater than
air pressure inside, there is always the possibility of accidental implosion.
WARNING
You must handle CRTs very carefully to avoid accidental
implosion and shattering glass. Use the following guidelines
and disposal procedure to remove and dispose of a CRT. These
guidelines and procedure are Digital policy for all CRTs more
than 7.6 cm (3 in) in diameter.
NOTE
This procedure supersedes all other tech tips about replacing
and disposing of CRTs. This procedure is for Digital personnel
only and is not intended for use by OEM and self-maintenance
customers.
Location
Work in areas where risks and exposure are limited to trained Digital
personnel. Only Digital personnel should be in the area during CRT
removal and replacement.