HSD10 Operation
VAX 4000 Model 108 User Information 4-29
FLASH Boot Utility Options
1) Download new Firmware Image
2) Change serial baud rate
9) Restart Controller
Option: 1
SREC Load Utility
To download the update the host dataport must be configured for
(x) baud, 8 bit, 1 stop, no parity. Flow ctrl must be XON/XOFF
SREC-I-BEGIN, Load Sequence beginning - enter CTRL/C to ABORT
6. The external communication system should now be used to send the upgrade image
file to the HSD10 (use an ASCII or Text file transfer command, do not use Binary
transfer). The exact command mechanism will be dependent upon the
communications application being used. When the image transfer is initiated, the
following will be displayed:
SREC-I-VER, Receiving code for HSD10 Version (x) /
The final '/' character will appear to rotate slowly to indicate image transfer progress.
Once the transfer completes, the following should be displayed, ending with the
Utility Options menu:
FLASH-I-LOADCPLT, Initiating Programming sequence
FLASH-I-ERASING, Erasing Sector ..1..2..3..4..5..6..7
FLASH-I-PROGRAMMING, Programming Sector ..1..2..3..4..5..6..7
FLASH-I-COMPLETE, FLASH Programming Complete
FLASH Boot Utility Options
1) Download new Firmware Image
2) Change serial baud rate
9) Restart Controller
Option:
Содержание VAX 4000 108
Страница 4: ......
Страница 36: ......
Страница 70: ...Getting Started 2 34 VAX 4000 Model 108 User Information MLO 013676 Figure 2 27 Connecting the Power Cord ...
Страница 82: ......
Страница 146: ......
Страница 152: ......
Страница 170: ......
Страница 206: ......
Страница 222: ......
Страница 226: ......
Страница 232: ......
Страница 243: ...Index Index 7 connecting 3 22 Volume shadowing 4 4 W Welcome xi ...