Diagnostic Test Errors
Table A–2 describes the Fast EtherWORKS PCI 10/100 adapter
diagnostic test error messages and the recommended corrective
actions for each group of messages.
Table A–2 Diagnostic Test Error Codes
Error Message
Recommended Actions
Registers Read/Write error
Ethernet Address ROM CRC
error
Ensure that the Fast Ethernet adapter is
seated securely in a PCI bus slot, or try
another available PCI bus slot.
Ensure that the adapter was installed
correctly during BIOS Setup: the PCI slot
is enabled, an IRQ number is assigned,
and bus mastering is enabled. (See
Appendix C for more information.)
1
Internal Loopback error
Interrupt Loopback error
IRQ conflict (when two adapters have
been assigned the same interrupt line), or
the PCI slot was not enabled. Check the
adapter’s settings in the EZWORKS
Installation utility. Use the BIOS
Setup utility, if available, to change
any settings.
1
CRC Logic error
This message indicates network-related
test failures. If the driver was installed
before running diagnostics, power down
your system, then start again.
1
Two Buffered Xmt/Rcv error
Chained Xmt/Rcv error
Force Collision error
Setup Frame Filter error
These messages indicate network-related
test failures. If the driver was installed
before running diagnostics, power down
your system, then start again.
1
1
If the problem persists, the adapter could be defective. Depending on where you
purchased the adapter, contact either your authorized DIGITAL distributor or DIGITAL
Technical Support.