Digital Dream Standalone Motion Controller
DDCS-Expert Users Manual
Page-27
4.5 Limit, Home and Probe Inputs
DDCSE Input and Output are the user-defined IO ports, In our example, we already set IN12,
IN11 and IN10 as the “ axis limit signal ” Input port, and we already set the IN09 as “ Probe ”
output port.
Please note that the limit switch type should be NPN Normal Open, and the voltage range is
24VDC.
Some users asked for the wiring methods for the probe with over-strock alarm, here we also
set one sample for it.
Figure 4-16 Proximity switch/Mecahnical switch and normal Probe wiring methods
Figure 4-17 The Probe sensor with over-strock alarm signal
Proximity switch
S1
S2
S3
Mechanical Switch
Probe
COM+
COM-
COM+
COM-
IN24
IN23
IN22
IN21
IN20
IN19
IN18
IN17
IN16
IN15
IN14
IN13
IN12
IN11
IN10
IN09
IN08
IN07
IN06
IN05
IN04
IN03
IN02
IN01
INPUT
NC
RED
DC24V
NO
AC/DC
0V
Over Strock Alarm signal
BROWN
ORANGE
GREY
GREEN
BLUE
NC
LED
I/F
Standard IF internal circuit
NPN Type limited switch with over-strock alarm signal,voltage DC24V.