CHAPTER 3. SETTING UP THE CD60/80M DRIVE 39
Energise
The energise edge connector signal allows a drive to be remotely
selected, depending upon the logic state of the controlling signal.
When a drive is shutdown or de-energised the motor may be turned
slowly by hand (if it is safe to do so) to allow the re-positioning of
mechanical components.
If you wish to use the energise input (TB1 pin 7) to energise the
drive, link setting ‘I’ must be made.
Motor Current
Motor current may be link adjusted to the values given in Table 3-1
depending upon your application requirements. The motor currents
quoted in Table 3-1 are RMS values and the chosen setting must not
exceed the current rating of the motor. Peak currents are
approximately 40% higher than the RMS values - the peak current
from the CD80M is therefore 11A.